Fuses

Image Part Number Description / PDF Quantity Rfq
BK/GMD-200-R

BK/GMD-200-R

PowerStor (Eaton)

FUSE GLASS 200MA 250VAC 5X20MM

794

0498150.MX1M5

0498150.MX1M5

Wickmann / Littelfuse

FUSE AUTO 150A 32VDC AUTO LINK

0

35621000029

35621000029

Wickmann / Littelfuse

FUSE CERAMIC 10A 440VAC 3AB 3AG

3938

0034.1007

0034.1007

Schurter

FUSE GLASS 5A 250VAC 3AB 3AG

100

0213.200MXP

0213.200MXP

Wickmann / Littelfuse

FUSE GLASS 200MA 250VAC 5X20MM

1000

3404.2470.11

3404.2470.11

Schurter

FUSE BRD MNT 250VAC/125VDC 2SMD

300200

7100.1060.13

7100.1060.13

Schurter

FUSE BOARD MNT 315MA 250VAC/VDC

87

SF-0402F160-2

SF-0402F160-2

J.W. Miller / Bourns

FUSE BOARD MOUNT 1.6A 32VDC 0402

1919

7100.1115.13

7100.1115.13

Schurter

FUSE BOARD MNT 1A 250VAC/VDC RAD

115

QA2410F1A25T

QA2410F1A25T

AEM

AUTOMOTIVE FUSE, 1.25A, 250VDC

2000

BK/S506-200-R

BK/S506-200-R

PowerStor (Eaton)

FUSE GLASS 200MA 250VAC 5X20MM

151

BK/MDL-12-R

BK/MDL-12-R

PowerStor (Eaton)

FUSE GLASS 12A 32VAC 3AB 3AG

150

0230004.VXP

0230004.VXP

Wickmann / Littelfuse

FUSE GLASS 4A 125VAC/VDC AXIAL

0

0678D5000-02

0678D5000-02

Bel Fuse, Inc.

FUSE SMT 3912 FAST 250V 5A

0

ANM-I-10A

ANM-I-10A

OptiFuse

FUSE AUTO 10A 32VDC BLADE MINI

0

0ACG-1000-TE

0ACG-1000-TE

Bel Fuse, Inc.

FUSE 500VDC 350VAC SMT 1A

0

ANR-I-25A

ANR-I-25A

OptiFuse

FUSE AUTO 25A 32VDC BLADE

0

74-5SC500MA

74-5SC500MA

NTE Electronics, Inc.

FUSE CERAMIC 500MA 250VAC 5X20MM

2298

SSQ 2 /5K

SSQ 2 /5K

Bel Fuse, Inc.

FUSE BOARD MNT 2A 125VAC/VDC SMD

0

2767383

2767383

Phoenix Contact

FUSE 5A RADIAL

0

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top