Fuses

Image Part Number Description / PDF Quantity Rfq
0272001.V

0272001.V

Wickmann / Littelfuse

FUSE BOARD MNT 1A 125VAC/VDC RAD

0

0697H6300-05

0697H6300-05

Bel Fuse, Inc.

FUSE BRD MNT 6.3A 350VAC 72VDC

446

0251005.MAT1L

0251005.MAT1L

Wickmann / Littelfuse

FUSE BRD MNT 5A 125VAC/VDC AXIAL

1520

AGX-1-1/4

AGX-1-1/4

PowerStor (Eaton)

FUSE GLASS 1.25A 250VAC 8AG

161270

3413.0008.24

3413.0008.24

Schurter

FUSE BRD MNT 160MA 125VAC 63VDC

0

AGC-10-R

AGC-10-R

PowerStor (Eaton)

FUSE GLASS 10A 250VAC 3AB 3AG

0

TSD-20A

TSD-20A

OptiFuse

GLASS - 5X20MM (IEC), SLOW 20A

3135

BK/GDB-160MA

BK/GDB-160MA

PowerStor (Eaton)

FUSE GLASS 160MA 250VAC 5X20MM

0

APS-15A

APS-15A

OptiFuse

FUSE AUTO 15A 32VDC BLADE MINI

2179

0ADAP0600-RE

0ADAP0600-RE

Bel Fuse, Inc.

FUSE CERM 0.6A 600V AXL

65

74-6FG1.25A

74-6FG1.25A

NTE Electronics, Inc.

FUSE GLASS 1.25A 250VAC 6X30MM

1775

FSA-P-10A

FSA-P-10A

OptiFuse

GLASS FUSE - 6.3X32MM, FAST 10A

56

0233007.MXP

0233007.MXP

Wickmann / Littelfuse

FUSE GLASS 7A 125VAC 5X20MM

6921000

FSA-12A

FSA-12A

OptiFuse

GLASS FUSE - 6.3X32MM, FAST 12A

3875

38314000410

38314000410

Wickmann / Littelfuse

FUSE BOARD MOUNT 4A 300VAC RAD

0

0326020.MXCCP

0326020.MXCCP

Wickmann / Littelfuse

FUSE CERM 20A 250VAC 125VDC 3AB

0

3-103-124

3-103-124

Schurter

MGA-A FUSE 3A SOLID STATE THIN F

0

0877004.MXEP

0877004.MXEP

Wickmann / Littelfuse

FUSE CERAMIC 4A 250VAC AXIAL

990

0034.3123.PT

0034.3123.PT

Schurter

FUSE GLASS 4A 250VAC 5X20MM

978

0314002.MXP

0314002.MXP

Wickmann / Littelfuse

FUSE CERM 2A 250VAC 125VDC 3AB

24

Fuses

Fuses are electrical safety devices that protect circuits from overcurrent conditions. As the oldest and most widely used circuit protection technology, fuses operate by breaking the circuit when current exceeds specified limits. Their importance in modern electronics spans from consumer devices to industrial machinery, preventing damage from short circuits, overloads, and fault conditions while ensuring system reliability and safety.

TypeFunctional FeaturesApplication Examples
Miniature Cartridge FusesCompact glass/ceramic body, fast-acting responsePower supplies, consumer electronics
Time-Delay FusesWithstands temporary current surges, slow-blow characteristicsMotors, transformers, switch-mode power supplies
High-Breaker FusesHandles extreme fault currents (>10kA), ceramic constructionIndustrial equipment, HVAC systems
Surface-Mount FusesMiniaturized SMD packaging for PCB integrationSmartphones, medical devices
Resettable Fuses (PTC)Polymer-based self-resetting functionalityUSB ports, battery protection circuits

Typical fuse construction includes: - Enclosure: Glass, ceramic, or plastic housing (dimensions standardized as 5x20mm, 6.3x32mm) - Fusible Element: Calibrated wire or etched metal strip (silver, copper, or alloy materials) - Filling Material: Sand/quartz for arc suppression in high-current models - Contact Terminals: Metal caps or surface-mount pads for electrical connection Modern designs incorporate laser-welded elements and precision-calibrated response mechanisms.

ParameterDescriptionImportance
Rated Current (In)Max normal operating current (0.1-250A range)Determines circuit protection threshold
Voltage RatingMax circuit voltage (32V-1000V DC/AC)Ensures safe arc interruption
Breaking CapacityFault current interruption capability (10A-300kA)Prevents catastrophic failure
Response Time0.1ms (fast-acting) to 10s (time-delay)Matches load characteristics
Trip Characteristic CurveI2t let-through energy ratingCoordinates with upstream devices

Key industries include: - Consumer Electronics: Mobile devices, home appliances - Automotive: Battery management systems, EV charging circuits - Industrial: Motor drives, PLC systems - Telecommunications: Base station power supplies, data center infrastructure - Renewable Energy: Solar inverters, wind turbine converters

ManufacturerRepresentative ProductKey Features
Littelfuse440 Series Ceramic Fuses1000V rating, 300kA breaking capacity
BussmannFWS-6 Class CCTime-delay protection for industrial motors
TE ConnectivityMini5FuseSMD 5x10mm package for space-constrained designs
Mitsubishi ElectricBF Series High-Rupture3-phase power system protection

Key considerations: 1. Match rated current/voltage with circuit parameters 2. Coordinate breaking capacity with system fault levels 3. Select response time per load type (e.g., inrush current in motors) 4. Consider environmental factors (temperature, vibration) 5. Verify regulatory certifications (UL/IEC standards) Example: Selecting a 5x20mm F1A 250V fuse with 1500A breaking capacity for a 120W power supply.

Emerging developments include: - Miniaturization: Sub-2mm SMD fuses for wearable devices - Smart integration: IoT-enabled fuses with real-time monitoring - Material innovation: Biodegradable polymer enclosures - High-voltage specialization: 1500V DC fuses for photovoltaic systems - Hybrid solutions: Combined fuse-circuit breaker architectures

RFQ BOM Call Skype Email
Top