Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
GFL2B163002

GFL2B163002

Altech Corporation

MCCB+EGFP 16A240V AC 300MA B TRI

0

S-UVT-24

S-UVT-24

Altech Corporation

UNDERVLTG TRIP ACDC 24V FOR S-TD

0

3BU50R

3BU50R

Altech Corporation

3BU50R50AMCBBCHAR3P 480Y/277VACU

0

3D03UL

3D03UL

Altech Corporation

3D03UL 0.3A CIRCUIT BREAKER D CH

0

DC2CU30L

DC2CU30L

Altech Corporation

DC2CU30L30A MCB CCHAR 2P 250VDC

0

GFR4D20100

GFR4D20100

Altech Corporation

EGFP+OL 20A480Y277V AC 100MA D T

0

UV48DCL

UV48DCL

Altech Corporation

CIRCUIT BREAK UNDERVOLT 48V DC C

0

2DU05R

2DU05R

Altech Corporation

2DU05R0.5A MCBDCHAR2P 480Y/277VA

0

1Z15UM

1Z15UM

Altech Corporation

1Z15UM 15A CIRCUIT BREAKER Z CHA

12

TR11-C-X-63-B-0-C-1.2A

TR11-C-X-63-B-0-C-1.2A

Altech Corporation

CIRCUIT BREAK TRIP BAND HEX MET

10

2E2.5UM

2E2.5UM

Altech Corporation

2E2.5UM 2.5A CIRCUIT BREAKER 3 C

18

GFL2B120302

GFL2B120302

Altech Corporation

MCCB+EGFP 12A240V AC 30MA B TRIP

0

2BU5R

2BU5R

Altech Corporation

2BU5R 5A MCBBCHAR2P 480Y/277VACU

0

1D63UR

1D63UR

Altech Corporation

1D63UR 63A MCB D CHAR 1 P 277VAC

36

2CU13R

2CU13R

Altech Corporation

2CU13R 13A MCBCCHAR2P 480Y/277VA

270

UTS150N-FTU-60

UTS150N-FTU-60

Altech Corporation

CIRCUIT BREAKER 60A/480V AC 3P 3

1

2B40UR

2B40UR

Altech Corporation

2B40UR 40A MCB B CHAR 2 P 480Y/2

12

UTE100N-FTU-40

UTE100N-FTU-40

Altech Corporation

CIRCUIT BREAKER 40A/480V AC 3P 3

0

3BU8R

3BU8R

Altech Corporation

3BU8R8AMCBBCHAR3P 480Y/277VACUL1

0

1C3DL

1C3DL

Altech Corporation

1C3DL 3A CIRCUIT BREAKER C CHAR

12

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure