Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
GFL2C061002

GFL2C061002

Altech Corporation

MCCB+EGFP 6A240V AC 100MA C TRIP

0

GFL2D050302

GFL2D050302

Altech Corporation

MCCB+EGFP 5A240V AC 30MA D TRIP

24

TR11-C-X-63-B-0-A-1.0A

TR11-C-X-63-B-0-A-1.0A

Altech Corporation

CIRCUIT BREAK TRIP BAND KNURL ME

40

GFR4B30100

GFR4B30100

Altech Corporation

EGFP+OL 30A480Y277V AC 100MA B T

0

3DU60L

3DU60L

Altech Corporation

3DU60L60AMCBDCHAR3P 240V ACUL489

0

1BU50R

1BU50R

Altech Corporation

1BU50R 50A MCB B CHAR 1P277VACUL

12

TR11-C-X-63-B-1-C-1.5A

TR11-C-X-63-B-1-C-1.5A

Altech Corporation

CIRCUIT BREAK TPBDVERMAHEX METNU

0

GFL2B05030SN

GFL2B05030SN

Altech Corporation

MCCB+EGFP 5A120240V AC 30MA B TR

0

2D12UR

2D12UR

Altech Corporation

2D12UR 12A MCB D CHAR 2 P 480Y/2

0

S-TS250HU-FTU-LL-200

S-TS250HU-FTU-LL-200

Altech Corporation

CIRCUIT BREAKER 200A480V AC 3P 6

0

GFL2B15300SN

GFL2B15300SN

Altech Corporation

MCCB+EGFP 15A120240V AC 300MA B

0

2D40UR

2D40UR

Altech Corporation

CIRCUIT BREAKER 40A MCB 2PUL1077

0

LX-20

LX-20

Altech Corporation

MMS AUXILIARY SWITCH SIDE MOUNT

0

1D16UR

1D16UR

Altech Corporation

1D16UR 16A MCB D CHAR 1 P 277VAC

12

GFR2D32030

GFR2D32030

Altech Corporation

EGFP+OL 32A277V AC 30MA D TRIP 1

0

2E4UM

2E4UM

Altech Corporation

2E4UM 4A CIRCUIT BREAKER E CHAR2

0

2C20DL

2C20DL

Altech Corporation

2C20DL 20A CIRCUIT BREAKER C CHA

0

GFR2D20100

GFR2D20100

Altech Corporation

EGFP+OL 20A277V AC 100MA D TRIP

2

GFL2B13100SN

GFL2B13100SN

Altech Corporation

MCCB+EGFP 13A120240V AC 100MA B

0

GFR2B16010

GFR2B16010

Altech Corporation

EGFP+OL 16A277V AC 10MA B TRIP 1

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top