Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
GFL2B06100S

GFL2B06100S

Altech Corporation

MCCB+EGFP 6A120240V AC 100MA B T

0

GFR4C15300

GFR4C15300

Altech Corporation

EGFP+OL 15A480Y277V AC 300MA C T

0

1D13UM

1D13UM

Altech Corporation

1D13UM 13A CIRCUIT BREAKER D CHA

0

GFL2C06100S

GFL2C06100S

Altech Corporation

MCCB+EGFP 6A120240V AC 100MA C T

0

1C10UR

1C10UR

Altech Corporation

1C10UR 10A MCB C CHAR 1 P 277VAC

0

3DU02L

3DU02L

Altech Corporation

3DU02L0.2AMCBDCHAR3P 480Y/277VAC

20

GFL2B40300SN

GFL2B40300SN

Altech Corporation

MCCB+EGFP 40A120240V AC 300MA B

0

GFR2C05010

GFR2C05010

Altech Corporation

EGFP+OL 5A277V AC 10MA C TRIP 1P

2

RP2303

RP2303

Altech Corporation

RP2303 40A 30MA 2P EARTH LEAKAGE

0

1Z1UL

1Z1UL

Altech Corporation

1Z1UL 1A CIRCUIT BREAKER Z CHAR

0

GFR4D13100

GFR4D13100

Altech Corporation

EGFP+OL 13A480Y277V AC 100MA D T

0

2CU63R

2CU63R

Altech Corporation

2CU63R 63A MCBCCHAR2P 480Y/277VA

0

GFR2B16030

GFR2B16030

Altech Corporation

EGFP+OL 16A277V AC 30MA B TRIP 1

0

3G63UM

3G63UM

Altech Corporation

3G63UM 63ACIRCUIT BREAKER G CHAR

0

2D32DL

2D32DL

Altech Corporation

2D32DL 32A CIRCUIT BREAKER D CHA

6

1CU12L

1CU12L

Altech Corporation

1CU12L12A MCB C CHAR 1P277VACUL4

24

GFR2C05300

GFR2C05300

Altech Corporation

EGFP+OL 5A277V AC 300MA C TRIP 1

0

1Z30UL

1Z30UL

Altech Corporation

1Z30UL 30A CIRCUIT BREAKER Z CHA

24

2CU02L

2CU02L

Altech Corporation

2CU02L0.2A MCBCCHAR2P 480Y/277VA

0

3G8UM

3G8UM

Altech Corporation

3G8UM 8ACIRCUIT BREAKER G CHAR3P

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure