Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
3BU13R

3BU13R

Altech Corporation

3BU13R13AMCBBCHAR3P 480Y/277VACU

16

2B1UR

2B1UR

Altech Corporation

2B1UR 1A MCB B CHAR 2 P 480Y/277

18

TR20-C-63S-B3-B-7.0A-2

TR20-C-63S-B3-B-7.0A-2

Altech Corporation

TR20SUPPROTBLTRIP WWHHORMA METKN

0

2Z3.5UM

2Z3.5UM

Altech Corporation

2Z3.5UM 3.5A CIRCUIT BREAKER Z C

0

2C63UL

2C63UL

Altech Corporation

2C63UL 63A CIRCUIT BREAKER C CHA

0

1Z12UM

1Z12UM

Altech Corporation

1Z12UM 12A CIRCUIT BREAKER Z CHA

0

3D05UL

3D05UL

Altech Corporation

3D05UL 0.5A CIRCUIT BREAKER D CH

0

3D16UL

3D16UL

Altech Corporation

3D16UL 16A CIRCUIT BREAKER D CHA

40

3C32UR

3C32UR

Altech Corporation

3C32UR 32A MCB C CHAR 3 P 480Y/2

12

1CU20R

1CU20R

Altech Corporation

1CU20R 20A MCB C CHAR 1P277VACUL

0

GFL2C050102

GFL2C050102

Altech Corporation

MCCB+EGFP 5A240V AC 10MA C TRIP

0

GFR2B05300

GFR2B05300

Altech Corporation

EGFP+OL 5A277V AC 300MA B TRIP 1

0

2DU3R

2DU3R

Altech Corporation

2DU3R3A MCBDCHAR2P 480Y/277VACUL

0

1DU12R

1DU12R

Altech Corporation

1DU12R12A MCB D CHAR 1P277VACUL1

0

3C25UR

3C25UR

Altech Corporation

3C25UR 25A MCB C CHAR 3 P 480Y/2

4

1Z30UM

1Z30UM

Altech Corporation

1Z30UM 30A CIRCUIT BREAKER Z CHA

0

2CU30R

2CU30R

Altech Corporation

2CU30R 30A MCBCCHAR2P 480Y/277VA

0

2Z32UM

2Z32UM

Altech Corporation

2Z32UM 32A CIRCUIT BREAKER Z CHA

6

GFL2D25010SN

GFL2D25010SN

Altech Corporation

MCCB+EGFP 25A120240V AC 10MA D T

0

1DU16L

1DU16L

Altech Corporation

1DU16L 16A MCB D CHAR 1P277VACUL

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure