Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
TR11-C-Y-63-B-0-C-9.0A

TR11-C-Y-63-B-0-C-9.0A

Altech Corporation

CIRCUIT BREAK SLIDE MET NUT 9A

0

1CU30L

1CU30L

Altech Corporation

1CU30L30A MCB C CHAR 1P277VACUL4

0

GFR2D20300

GFR2D20300

Altech Corporation

EGFP+OL 20A277V AC 300MA D TRIP

0

3D50UL

3D50UL

Altech Corporation

3D50UL 50A CIRCUIT BREAKER D CHA

44

GFL2C10030S

GFL2C10030S

Altech Corporation

MCCB+EGFP 10A120240V AC 30MA C T

0

GFL2C16300SN

GFL2C16300SN

Altech Corporation

MCCB+EGFP 16A120240V AC 300MA C

0

1CU8L

1CU8L

Altech Corporation

1CU8L8.0A MCB C CHAR 1P277VACUL4

132

1Z25UM

1Z25UM

Altech Corporation

1Z25UM 25A CIRCUIT BREAKER Z CHA

0

2B13UM

2B13UM

Altech Corporation

2B13UM 13A CIRCUIT BREAKER B CHA

0

1D1UR

1D1UR

Altech Corporation

1D1UR 1A MCB D CHAR 1 P 277VAC U

36

MA1.0UM

MA1.0UM

Altech Corporation

MA10UM 063-10A 3P MOTORPROTECTOR

0

3B2UM

3B2UM

Altech Corporation

CIRCUIT BREAKER2UM 2A B CHAR3P48

0

DC2DU02L

DC2DU02L

Altech Corporation

DC2DU02L02A MCBDCHAR 2P250VDCUL4

0

2C4DL

2C4DL

Altech Corporation

2C4DL 4A CIRCUIT BREAKER C CHAR

0

RP4203

RP4203

Altech Corporation

RP4203 25A 30MA 4P EARTH LEAKAGE

0

2D03UL

2D03UL

Altech Corporation

2D03UL 0.3A CIRCUIT BREAKER D CH

0

2Z2UM

2Z2UM

Altech Corporation

2Z2UM 2A CIRCUIT BREAKER Z CHAR2

0

GFR2D25010

GFR2D25010

Altech Corporation

EGFP+OL 25A277V AC 10MA D TRIP 1

0

2E05UM

2E05UM

Altech Corporation

2E05UM 0.5A CIRCUIT BREAKER 3 CH

12

GFL2C32300S

GFL2C32300S

Altech Corporation

MCCB+EGFP 32A120240V AC 300MA C

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email