Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
1B3.5UM

1B3.5UM

Altech Corporation

1B3.5UM 3.5A CIRCUIT BREAKER B C

0

1C05UL

1C05UL

Altech Corporation

1C05UL 0.5A CIRCUIT BREAKER C CH

0

GFR2D10010

GFR2D10010

Altech Corporation

EGFP+OL 10A277V AC 10MA D TRIP 1

1

GFL2B16010SN

GFL2B16010SN

Altech Corporation

MCCB+EGFP 16A120240V AC 10MA B T

0

GFL2B30100S

GFL2B30100S

Altech Corporation

MCCB+EGFP 30A120240V AC 100MA B

0

2D8UM

2D8UM

Altech Corporation

CIRCUIT BREAKER 8A 2P UL508

306

1DU20R

1DU20R

Altech Corporation

1DU20R20A MCB D CHAR 12 1P277VAC

96

GFR4B25100

GFR4B25100

Altech Corporation

EGFP+OL 25A480Y277V AC 100MA B T

0

S-TD125NU-FMU-LL-60

S-TD125NU-FMU-LL-60

Altech Corporation

CIRCUIT BREAKER 60A480V AC 3P 35

0

GFL2D08010SN

GFL2D08010SN

Altech Corporation

MCCB+EGFP 8A120240V AC 10MA D TR

0

1C25UM

1C25UM

Altech Corporation

1C25UM 25A CIRCUIT BREAKER C CHA

12

GFL2B16300S

GFL2B16300S

Altech Corporation

MCCB+EGFP 16A120240V AC 300MA B

0

GFL2C251002

GFL2C251002

Altech Corporation

MCCB+EGFP 25A240V AC 100MA C TRI

0

2Z10UL

2Z10UL

Altech Corporation

2Z10UL 10A CIRCUIT BREAKER Z CHA

0

1D25UM

1D25UM

Altech Corporation

1D25UM 25A CIRCUIT BREAKER D CHA

0

UV24ACR

UV24ACR

Altech Corporation

CIRCUIT BREAK UNDERVOLT 24V AC C

0

GFR2B32100

GFR2B32100

Altech Corporation

EGFP+OL 32A277V AC 100MA B TRIP

0

GFL2D13010S

GFL2D13010S

Altech Corporation

MCCB+EGFP 13A120240V AC 10MA D T

0

1C6UR

1C6UR

Altech Corporation

1C6UR 6A MCB C CHAR 1 P 277VAC U

36

3C16UL

3C16UL

Altech Corporation

3C16UL 16A CIRCUIT BREAKER C CHA

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure