Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
2C05UM

2C05UM

Altech Corporation

2C05UM 0.5A CIRCUIT BREAKER C CH

0

GFL2C12100S

GFL2C12100S

Altech Corporation

MCCB+EGFP 12A120240V AC 100MA C

0

UV60ACL

UV60ACL

Altech Corporation

CIRCUIT BREAK UNDERVOLT 60V AC C

0

MS6.3

MS6.3

Altech Corporation

MS63 MANUAL MOTOR CONTROLLER 4-6

0

1C10DL

1C10DL

Altech Corporation

1C10DL 10A CIRCUIT BREAKER C CHA

0

GFL2D15010S

GFL2D15010S

Altech Corporation

MCCB+EGFP 15A120240V AC 10MA D T

0

1D30UR

1D30UR

Altech Corporation

1D30UR 30A MCB D CHAR 1 P 277VAC

156

UTS250N-FTU-175

UTS250N-FTU-175

Altech Corporation

CIRCUIT BREAKER 175A/480V AC 3P

0

GF225300

GF225300

Altech Corporation

EGFP 25A277V AC 300MA 1P+N 5060H

0

3D8UR

3D8UR

Altech Corporation

3D8UR 8A MCB D CHAR 3 P 480Y/277

0

3C3.5UM

3C3.5UM

Altech Corporation

3C3.5UM 3.5A CIRCUIT BREAKER C C

0

DC2CU15L

DC2CU15L

Altech Corporation

DC2CU15L15A MCB CCHAR 2P 250VDC

0

3DU4L

3DU4L

Altech Corporation

3DU4L4AMCBDCHAR3P 480Y/277VACUL4

0

1C60UM

1C60UM

Altech Corporation

1C60UM 60A CIRCUIT BREAKER C CHA

0

1D10UR

1D10UR

Altech Corporation

1D10UR 10A MCB D CHAR 1 P 277VAC

48

1DU02L

1DU02L

Altech Corporation

1DU02L 0.2A MCB D CHAR 1P277VACU

0

GFR2D16010

GFR2D16010

Altech Corporation

EGFP+OL 16A277V AC 10MA D TRIP 1

0

2D40DL

2D40DL

Altech Corporation

CIRCUIT BREAKER 40A 2P UL489

6

GFR2B08010

GFR2B08010

Altech Corporation

EGFP+OL 8A277V AC 10MA B TRIP 1P

0

GFR2C06300

GFR2C06300

Altech Corporation

EGFP+OL 6A277V AC 300MA C TRIP 1

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure