Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
DC2DU05L

DC2DU05L

Altech Corporation

DC2DU05L05A MCBDCHAR 2P250VDCUL4

6

DC2CU40L

DC2CU40L

Altech Corporation

DC2CU40L40A MCB CCHAR 2P 250VDC

0

2E30UM

2E30UM

Altech Corporation

2E30UM 30A CIRCUIT BREAKER E CHA

0

GFL2D10300S

GFL2D10300S

Altech Corporation

MCCB+EGFP 10A120240V AC 300MA D

0

UTS250N-FTU-250

UTS250N-FTU-250

Altech Corporation

CIRCUIT BREAKER 250A/480V AC 3P

0

2Z30UM

2Z30UM

Altech Corporation

2Z30UM 30A CIRCUIT BREAKER Z CHA

18

GFR2B30100

GFR2B30100

Altech Corporation

EGFP+OL 30A277V AC 100MA B TRIP

0

3Z40UM

3Z40UM

Altech Corporation

3Z40UM 40A CIRCUIT BREAKER Z CHA

0

2E03UM

2E03UM

Altech Corporation

2E03UM 0.3A CIRCUIT BREAKER 3 CH

12

2C60UL

2C60UL

Altech Corporation

2C60UL 60A CIRCUIT BREAKER C CHA

0

2CU3L

2CU3L

Altech Corporation

2CU3L3.0A MCBCCHAR2P 480Y/277VAC

0

GFR4D32300

GFR4D32300

Altech Corporation

EGFP+OL 32A480Y277V AC 300MA D T

0

GFL2C13300SN

GFL2C13300SN

Altech Corporation

MCCB+EGFP 13A120240V AC 300MA C

0

1D50UM

1D50UM

Altech Corporation

1D50UM 50A CIRCUIT BREAKER D CHA

24

2DU02L

2DU02L

Altech Corporation

2DU02L0.2A MCBDCHAR2P 480Y/277VA

0

2G3.5UM

2G3.5UM

Altech Corporation

2G3.5UM 3.5A CIRCUIT BREAKER G C

0

3D3.5UM

3D3.5UM

Altech Corporation

3D3.5UM 3.5A CIRCUIT BREAKER D C

0

S-TD125NU-FTU-LL-80

S-TD125NU-FTU-LL-80

Altech Corporation

CIRCUIT BREAKER 80A480V AC 3P 35

0

1DU4L

1DU4L

Altech Corporation

1DU4L 4.0A MCB D CHAR 1P277VACUL

24

1C075UM

1C075UM

Altech Corporation

1C075UM 0.75ACIRCUIT BREAKER C C

12

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure