Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
3C15UR

3C15UR

Altech Corporation

3C15UR 15A MCB C CHAR 3 P 480Y/2

24

3C16UM

3C16UM

Altech Corporation

3C16UM 16A CIRCUIT BREAKER C CHA

0

UTS150N-FTU-100

UTS150N-FTU-100

Altech Corporation

CIRCUIT BREAKER 100A/480V AC 3P

0

GFL2D083002

GFL2D083002

Altech Corporation

MCCB+EGFP 8A240V AC 300MA D TRIP

0

2E60UM

2E60UM

Altech Corporation

2E60UM 60A CIRCUIT BREAKER E CHA

0

2C4UL

2C4UL

Altech Corporation

2C4UL 4A CIRCUIT BREAKER C CHAR2

66

3BU12R

3BU12R

Altech Corporation

3BU12R12AMCBBCHAR3P 480Y/277VACU

0

1DU50R

1DU50R

Altech Corporation

1DU50R50A MCB D CHAR 1P277VACUL1

0

1C12UR

1C12UR

Altech Corporation

1C12UR 12A MCB C CHAR 1 P 277VAC

0

3DU12L

3DU12L

Altech Corporation

3DU12L12AMCBDCHAR3P 480Y/277VACU

80

S-TS250NU-FTU-LL-150

S-TS250NU-FTU-LL-150

Altech Corporation

CIRCUIT BREAKER 150A480V AC 3P 3

0

2C35UL

2C35UL

Altech Corporation

2C35UL 35A CIRCUIT BREAKER C CHA

12

1C16DL

1C16DL

Altech Corporation

1C16DL 16A CIRCUIT BREAKER C CHA

0

GFL2D150102

GFL2D150102

Altech Corporation

MCCB+EGFP 15A240V AC 10MA D TRIP

18

2C12UL

2C12UL

Altech Corporation

2C12UL 12A CIRCUIT BREAKER C CHA

0

GFR4B05100

GFR4B05100

Altech Corporation

EGFP+OL 5A480Y277V AC 100MA B TR

0

2C1UM

2C1UM

Altech Corporation

2C1UM 1A CIRCUIT BREAKER C CHAR2

0

2E15UM

2E15UM

Altech Corporation

2E15UM 15A CIRCUIT BREAKER E CHA

12

GFR4B10100

GFR4B10100

Altech Corporation

EGFP+OL 10A480Y277V AC 100MA B T

1

GFR2D15030

GFR2D15030

Altech Corporation

EGFP+OL 15A277V AC 30MA D TRIP 1

2

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top