Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
SU2D3UC

SU2D3UC

Weidmuller

CB PROTECTOR 1077 2P D 3A ACDC

43

9926251550

9926251550

Weidmuller

CIR BRKR MAG-HYDR 50A 240VAC

0

9925430000

9925430000

Weidmuller

CIR BRKR 10A 277VAC 50VDC

0

9929830000

9929830000

Weidmuller

CIR BRKR 13A 480VAC 110VDC

0

9926251525

9926251525

Weidmuller

CIR BRKR MAG-HYDR 25A 240VAC

0

991380

991380

Weidmuller

CIR BRKR THRMMAG 8A 480VAC 65VDC

0

9913201302

9913201302

Weidmuller

CB2213-10 W/O AUX T1 2.0A

0

9912251302

9912251302

Weidmuller

CB2212-10 W/O AUX T1 2.5A

0

BR2C7AC

BR2C7AC

Weidmuller

CB MCB 2P 7A

0

9101303200

9101303200

Weidmuller

CIR BRKR 1.2A 250VAC 80VDC

0

BR2C16AC

BR2C16AC

Weidmuller

CB MCB 2P 16A

0

BR3D63AC

BR3D63AC

Weidmuller

CB MCB 3P 63A

0

9925800000

9925800000

Weidmuller

CIR BRKR 63A 480VAC 110VDC

0

9922200003

9922200003

Weidmuller

CIR BRKR 20A 480VAC 65VDC

0

9974331902

9974331902

Weidmuller

CBH8341-10 10A W/O AUX

0

9925500000

9925500000

Weidmuller

CIR BRKR 63A 277VAC 50VDC

0

9912500002

9912500002

Weidmuller

CB2212-10-W/O AUX 5.0A

0

BR3C20AC

BR3C20AC

Weidmuller

BRANCH/3P CCTBRKR/C CURVE/20A

0

BR1D20AC

BR1D20AC

Weidmuller

BRANCH/1P CCTBRKR/D CURVE/20A

0

SU3D7AC

SU3D7AC

Weidmuller

CB PROTECTOR 3P 7A

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure