Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9912301302

9912301302

Weidmuller

CB2212-10 W/O AUX T1 3.0A

0

9912601309

9912601309

Weidmuller

CB2212-10 W/N/O AUX 6A TD

0

9913800003

9913800003

Weidmuller

CIR BRKR THRMMAG 8A 480VAC 65VDC

0

9129713200

9129713200

Weidmuller

CIR BRKR THRMMAG 4A 250VAC 80VDC

0

9926263520

9926263520

Weidmuller

CIR BRKR MAG-HYDR 20A 480VAC

0

SU3D4UC

SU3D4UC

Weidmuller

CB PROTECTOR 1077 3P D 4A ACDC

38

9124273200

9124273200

Weidmuller

CIR BRKR 400MA 250VAC 80VDC

0

BR2C13UC

BR2C13UC

Weidmuller

CB MCB 489 2P C 13A ACDC

65

9926253001

9926253001

Weidmuller

QL-3(13)-DM-KM-1A

0

9926252910

9926252910

Weidmuller

QY-2-13-DM-U2-10

132

9911401105

9911401105

Weidmuller

CB2210-T210-K0F1-H131 4A

0

9923200003

9923200003

Weidmuller

CIR BRKR 20A 480VAC 65VDC

0

9926252830

9926252830

Weidmuller

QY-2-13-DM-U2-30-B12

0

9912800005

9912800005

Weidmuller

CB2212-10 8A NC AUX

0

9912300002

9912300002

Weidmuller

CB2212-10 W/O AUX. 3A

0

9926282025

9926282025

Weidmuller

CIR BRKR MAG-HYDR 25A 240VAC

0

1278790000

1278790000

Weidmuller

CIR BRKR THRM 10A 28VDC

0

6720005381

6720005381

Weidmuller

CIR BRKR THRM 1A 24VDC SLD SWCH

0

9124333500

9124333500

Weidmuller

CIR BRKR 1.8A 250VAC 80VDC

0

SU1D63UC

SU1D63UC

Weidmuller

CB PROTECTOR 1077 1P D 63A ACDC

153

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure