Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9104153200

9104153200

Weidmuller

CIR BRKR THRMMAG 7A 250VAC 80VDC

0

99110521

99110521

Weidmuller

CB2210-10 W/O AUX. 5A T2

0

9926281505

9926281505

Weidmuller

CIR BRKR MAG-HYDR 5A 240VAC

0

9120353500

9120353500

Weidmuller

CIR BRKR 100MA 250VAC 80VDC

0

9124223500

9124223500

Weidmuller

CIR BRKR 50MA 250VAC 65VDC

0

9913801302

9913801302

Weidmuller

CB2213-10 W/O AUX T1 8.0A

0

9922321302

9922321302

Weidmuller

CB2212-10 W/O AUX T1 32A

0

9926263502

9926263502

Weidmuller

CIR BRKR MAG-HYDR 2A 480VAC

0

1278750000

1278750000

Weidmuller

CIRCUIT BREAKER THRM 5A 28VDC

10

9926282020

9926282020

Weidmuller

CIR BRKR MAG-HYDR 20A 240VAC

0

SU2C40UC

SU2C40UC

Weidmuller

CB PROTECTOR 1077 2P C 40A ACDC

46

9913151302

9913151302

Weidmuller

CB2210-TI W.O. AUX 1.5A

0

BR1C32UC

BR1C32UC

Weidmuller

CB MCB 489 1P C 32A ACDC

12

9124093200

9124093200

Weidmuller

CIR BRKR 400MA 250VAC 80VDC

0

BR2D35UC

BR2D35UC

Weidmuller

CB MCB 489 2P D 35A ACDC

53

6720005474

6720005474

Weidmuller

ESX10-T 8-UNIT BLOCK 1=PKG/4

32

BR2C60UC

BR2C60UC

Weidmuller

CB MCB 489 2P C 60A ACDC

63

9913401302

9913401302

Weidmuller

CB2213-10 T2 W/O AUX 4.0A

0

9911501500

9911501500

Weidmuller

2210-T210-KOF2-H131-5A

15

9974271902

9974271902

Weidmuller

CB 8340 - .25 AMPS

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top