Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9970590000

9970590000

Weidmuller

CQB 10 STRAIGHT COMB 2/IP

0

BR3C63UC

BR3C63UC

Weidmuller

CB MCB 489 3P C 63A ACDC

106

9926271502

9926271502

Weidmuller

CIR BRKR MAG-HYDR 2A 240VAC

0

6720005353

6720005353

Weidmuller

ESX10-TC-114-DC12V-3A-E

12

9926252013

9926252013

Weidmuller

CIR BRKR MAG-HYDR 13A 240VAC

0

SU3D12UC

SU3D12UC

Weidmuller

CB PROTECTOR 1077 3P D 12A ACDC

80

9926272001

9926272001

Weidmuller

CIR BRKR MAG-HYDR 1A 240VAC

0

6720005363

6720005363

Weidmuller

ESX10-TB-114-DC24V-3A-E

24

BR1D16UC

BR1D16UC

Weidmuller

CB MCB 489 1P D 16A ACDC

110

BR3C12UC

BR3C12UC

Weidmuller

CB MCB 489 3P C 12A ACDC

53

9911080005

9911080005

Weidmuller

CIR BRKR 800MA 480VAC 65VDC

0

9926262525

9926262525

Weidmuller

CIR BRKR MAG-HYDR 25A 480VAC

0

9926252820

9926252820

Weidmuller

QY-2-13-DM-U2-125V

156

9912020003

9912020003

Weidmuller

CIR BRKR 200MA 480VAC 65VDC

0

9124143500

9124143500

Weidmuller

CIR BRKR 1.8A 250VAC 80VDC

17

SU3D30UC

SU3D30UC

Weidmuller

CB PROTECTOR 1077 3P D 30A ACDC

73

9913051302

9913051302

Weidmuller

CB2213-10 W/O AUX T1 0.5A

0

SU3D6UC

SU3D6UC

Weidmuller

CB PROTECTOR 1077 3P D 6A ACDC

61

9926271025

9926271025

Weidmuller

CIR BRKR MAG-HYDR 25A 120VAC

0

9912061302

9912061302

Weidmuller

CB2212-10 W/O AUX T1 0.6A

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email