Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9912101105

9912101105

Weidmuller

CB2212-10 W/NC AUX 1A

0

9926283010

9926283010

Weidmuller

QL-AT-3(13)-DM-KM-10A

0

9129613200

9129613200

Weidmuller

CIR BRKR THRMMAG 1A 250VAC 80VDC

0

9970580000

9970580000

Weidmuller

CQB 4 STRAIGHT COMB 2/IP

0

BR1D50UC

BR1D50UC

Weidmuller

CB MCB 489 1P D 50A ACDC

0

6720005473

6720005473

Weidmuller

ESX10-TC-124-DC12V-10A-E

8

9921321302

9921321302

Weidmuller

CB2211-10 W/O AUX T1 32.0A

0

9926281515

9926281515

Weidmuller

CIR BRKR MAG-HYDR 15A 240VAC

0

9926251402

9926251402

Weidmuller

QY-1-13-DM-1-02

0

9921160005

9921160005

Weidmuller

CIR BRKR 16A 480VAC 65VDC

0

9124293500

9124293500

Weidmuller

CIR BRKR 700MA 250VAC 80VDC

0

SU3C7UC

SU3C7UC

Weidmuller

CB PROTECTOR 1077 3P C 7A ACDC

51

9124343200

9124343200

Weidmuller

CIR BRKR 3.5A 250VAC 80VDC

0

9911201300

9911201300

Weidmuller

CIR BRKR THRMMAG 2A 277VAC 65VDC

0

9926263510

9926263510

Weidmuller

CIR BRKR MAG-HYDR 10A 480VAC

0

9124173500

9124173500

Weidmuller

CIR BRKR 4.5A 250VAC 80VDC

0

9913080003

9913080003

Weidmuller

CIR BRKR 800MA 480VAC 65VDC

0

9913250003

9913250003

Weidmuller

CIR BRKR 2.5A 480VAC 65VDC

0

9921321102

9921321102

Weidmuller

CB2210-10 F1 W/O AUX. 32A

0

9911011102

9911011102

Weidmuller

CB2211-10 W/O AUX 1A

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure