Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9926272510

9926272510

Weidmuller

CIR BRKR MAG-HYDR 10A 480VAC

0

SU3D7UC

SU3D7UC

Weidmuller

CB PROTECTOR 1077 3P D 7A ACDC

40

9926272010

9926272010

Weidmuller

CIR BRKR MAG-HYDR 10A 240VAC

0

9124423500

9124423500

Weidmuller

CIR BRKR THRMMAG 9A 250VAC 80VDC

0

9911801205

9911801205

Weidmuller

2210-T210-K0M3-8A

0

9129683200

9129683200

Weidmuller

CIR BRKR 10A 250VAC 80VDC

0

9911501502

9911501502

Weidmuller

CB2210-10 10A W/O AUX F5A

0

9921120002

9921120002

Weidmuller

CB2211-10-W/O AUX 12A

0

BR2D60UC

BR2D60UC

Weidmuller

CB MCB 489 2P D 60A ACDC

0

992110

992110

Weidmuller

CIR BRKR 10A 480VAC 65VDC

16

9911501105

9911501105

Weidmuller

CB2210-T210-K0F1-H121-5A

0

9926251530

9926251530

Weidmuller

QZ-1-13-D-2-30

12

SU3C12UC

SU3C12UC

Weidmuller

CB PROTECTOR 1077 3P C 12A ACDC

28

BR2D32UC

BR2D32UC

Weidmuller

CB MCB 489 2P D 32A ACDC

46

9926252930

9926252930

Weidmuller

QY-2-13-DM-U2-30

30

9911021302

9911021302

Weidmuller

CB2211-10 W/O AUX T1 0.2A

0

9926282002

9926282002

Weidmuller

CIR BRKR MAG-HYDR 2A 240VAC

0

9926261025

9926261025

Weidmuller

CIR BRKR MAG-HYDR 25A 120VAC

96

9911400002

9911400002

Weidmuller

CB2211-10 W/O AUX 4.0A

0

BR3D63UC

BR3D63UC

Weidmuller

CB MCB 489 3P D 63A ACDC

37

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email