Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
SU2C2UC

SU2C2UC

Weidmuller

CB PROTECTOR 1077 2P C 2A ACDC

5455

9926251504

9926251504

Weidmuller

CIR BRKR MAG-HYDR 4A 240VAC

323

BR3C30UC

BR3C30UC

Weidmuller

CB MCB 489 3P C 30A ACDC

29326

9926252025

9926252025

Weidmuller

CIR BRKR MAG-HYDR 25A 240VAC

278

BR2D1UC

BR2D1UC

Weidmuller

CB MCB 489 2P D 1A ACDC

1091

9926251005

9926251005

Weidmuller

CIR BRKR MAG-HYDR 5A 120VAC

206668

SU1C3UC

SU1C3UC

Weidmuller

CB PROTECTOR 1077 1P C 3A ACDC

671269

9926252560

9926252560

Weidmuller

CIR BRKR MAG-HYDR 60A 480VAC

12

BR3C15UC

BR3C15UC

Weidmuller

CB MCB 489 3P C 15A ACDC

1164

1278910000

1278910000

Weidmuller

CIR BRKR THRM 500MA 250VAC 65VDC

18135

9926252015

9926252015

Weidmuller

CIR BRKR MAG-HYDR 15A 240VAC

646

BR2C4UC

BR2C4UC

Weidmuller

CB MCB 489 2P C 4A ACDC

4130

9926251001

9926251001

Weidmuller

CIR BRKR MAG-HYDR 1A 120VAC

71

SU1C2UC

SU1C2UC

Weidmuller

CB PROTECTOR 1077 1P C 2A ACDC

42892

9926251503

9926251503

Weidmuller

CIR BRKR MAG-HYDR 3A 240VAC

5133

6720005331

6720005331

Weidmuller

ESX10-TC-124-DC12V-1A-E

525

BR1C8UC

BR1C8UC

Weidmuller

CB MCB 489 1P C 8A ACDC

1519968

9926252003

9926252003

Weidmuller

CIR BRKR MAG-HYDR 3A 240VAC

6119

BR2C20UC

BR2C20UC

Weidmuller

CB MCB 489 2P C 20A ACDC

6165

BR3C1UC

BR3C1UC

Weidmuller

CB MCB 489 3P C 1A ACDC

757

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure