Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9926252002

9926252002

Weidmuller

CIR BRKR MAG-HYDR 2A 240VAC

185210

SU1C10UC

SU1C10UC

Weidmuller

CIR BRKR THERM-MAG 10A LEVER

10898

SU1C20UC

SU1C20UC

Weidmuller

CB PROTECTOR 1077 1P C 20A ACDC

24810

SU1C25UC

SU1C25UC

Weidmuller

CB PROTECTOR 1077 1P C 25A ACDC

26427

9101403500

9101403500

Weidmuller

CIR BRKR 1.5A 250VAC 80VDC

52181

9926251906

9926251906

Weidmuller

QY-1-13-DM-2-06

17144

1278840000

1278840000

Weidmuller

CIR BRKR THRM 100MA 250VAC 65VDC

5

9926251903

9926251903

Weidmuller

CIR BRKR MAG-HYDR 3A 80VDC LEVER

3754

9926251500

9926251500

Weidmuller

QZ-1-13-D-2-005

1931

9926252215

9926252215

Weidmuller

QL-2-13-DM-1-15

7912

9926291120

9926291120

Weidmuller

CIR BRKR MAG-HYDR 20A 240VAC

452

9926251508

9926251508

Weidmuller

CIR BRKR MAG-HYDR 8A 240VAC

6

9926251505

9926251505

Weidmuller

CIR BRKR MAG-HYDR 5A 240VAC

2680

9926253530

9926253530

Weidmuller

CIR BRKR MAG-HYDR 30A 480VAC

1

9926251501

9926251501

Weidmuller

CIR BRKR MAG-HYDR 1A 240VAC

2067

BR1C20UC

BR1C20UC

Weidmuller

CB MCB 489 1P C 20A ACDC

2912517

1278990000

1278990000

Weidmuller

CIR BRKR THRM 3A 250VAC 65VDC

1445

BR3C3UC

BR3C3UC

Weidmuller

CB MCB 489 3P C 3A ACDC

48

9926251506

9926251506

Weidmuller

CIR BRKR MAG-HYDR 6A 240VAC

878

SU1C40UC

SU1C40UC

Weidmuller

CB PROTECTOR 1077 1P C 40A ACDC

14632

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top