Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
SU1D3UC

SU1D3UC

Weidmuller

CB PROTECTOR 1077 1P D 3A ACDC

1162

BR2C5UC

BR2C5UC

Weidmuller

CB MCB 489 2P C 5A ACDC

7143

BR1D15UC

BR1D15UC

Weidmuller

CB MCB 489 1P D 15A ACDC

21551

BR3C5UC

BR3C5UC

Weidmuller

CB MCB 489 3P C 5A ACDC

4168

9124213500

9124213500

Weidmuller

CIR BRKR 16A 250VAC 80VDC

523

BR2C2UC

BR2C2UC

Weidmuller

CB MCB 489 2P C 2A ACDC

9286

991150

991150

Weidmuller

CIR BRKR THRMMAG 5A 480VAC 65VDC

5

BR2C30UC

BR2C30UC

Weidmuller

CB MCB 489 2P C 30A ACDC

5304

9101003500

9101003500

Weidmuller

CIR BRKR 500MA 250VAC 80VDC

23365

BR2C40UC

BR2C40UC

Weidmuller

CB MCB 489 2P C 40A ACDC

36143

9926252004

9926252004

Weidmuller

CIR BRKR MAG-HYDR 4A 240VAC

19173

BR2D3UC

BR2D3UC

Weidmuller

CB MCB 489 2P D 3A ACDC

1154

9926251020

9926251020

Weidmuller

CIR BRKR MAG-HYDR 20A 120VAC

123367

9926252020

9926252020

Weidmuller

CIR BRKR MAG-HYDR 20A 240VAC

61300

9926253510

9926253510

Weidmuller

CIR BRKR MAG-HYDR 10A 480VAC

0

SU1C1UC

SU1C1UC

Weidmuller

CB PROTECTOR 1077 1P C 1A ACDC

6091757

BR1D3UC

BR1D3UC

Weidmuller

CB MCB 489 1P D 3A ACDC

271126

9921200005

9921200005

Weidmuller

CIR BRKR 20A 480VAC 65VDC

457

9102003500

9102003500

Weidmuller

CIR BRKR 15A 250VAC 80VDC

6459

BR1C30UC

BR1C30UC

Weidmuller

CB MCB 489 1P C 30A ACDC

2677

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure