Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4435.0629

4435.0629

Schurter

CIR BRKR THRM 8A 240VAC 32VDC

20

4435.0311

4435.0311

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

7

4435.0109

4435.0109

Schurter

CIR BRKR THRM 240VAC ROCKER

20

TS-701-HT-25

TS-701-HT-25

Schurter

CIR BRKR THRM 25A 250VAC 50VDC

65400

4430.1629

4430.1629

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

25

4420.0678

4420.0678

Schurter

CIR BRKR THRM MAG 13A 480V 65V

0

4435.017

4435.017

Schurter

CIR BRKR THRM 3A 240VAC 32VDC

0

4435.0294

4435.0294

Schurter

CIR BRKR THRM 2A 240VAC 32VDC

9

4435.0046

4435.0046

Schurter

CIR BRKR THRM 8A 240VAC 60VDC

5

4435.0624

4435.0624

Schurter

CIR BRKR THRM 3.5A 240VAC 32VDC

19

4435.0201

4435.0201

Schurter

CIR BRKR THRM 3A 240VAC 32VDC

40

4435.0374

4435.0374

Schurter

CIR BRKR THRM 3A 240VAC 60VDC

17

4410.0106

4410.0106

Schurter

CIR BRKR THRM 10A 240VAC 28VDC

19

4404.0007

4404.0007

Schurter

CIR BRKR THRM 5A 240VAC 48VDC

3585

4435.0633

4435.0633

Schurter

CIR BRKR THRM 15A 240VAC 32VDC

13

4435.0263

4435.0263

Schurter

CIR BRKR THRM 240VAC 60VDC

10

4430.2721

4430.2721

Schurter

CIR BRKR THRM 6A 240VAC 60VDC

17

4430.1826

4430.1826

Schurter

CIR BRKR THRM 12A 240VAC 60VDC

0

4435.0022

4435.0022

Schurter

CIR BRKR THRM 3A 240VAC 60VDC

0

4430.256

4430.256

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

20

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure