Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
TS-701-HT-10H

TS-701-HT-10H

Schurter

CIR BRKR THRM 10A 250VAC 50VDC

73200

4410.9019

4410.9019

Schurter

CIR BRKR THRM 15A 240VAC 28VDC

19

4420.0232

4420.0232

Schurter

CIR BRKR THRM MAG 25A 277V 65V

17

4430.1129

4430.1129

Schurter

CIR BRKR THRM 240VAC 60VDC

2

4435.0108

4435.0108

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

6

4420.0608

4420.0608

Schurter

CIR BRKR THRM MAG 7A 480V 65V

0

4435.021

4435.021

Schurter

CIR BRKR THRM 20A 240VAC 32VDC

17

4430.0428

4430.0428

Schurter

CIR BRKR THRM 4.5A 240VAC 60VDC

17

4400.0523

4400.0523

Schurter

CIR BRKR THRM 3A 240VAC 48VDC

0

4420.0249

4420.0249

Schurter

CIR BRKR THRM MAG 40A 360 VDC

0

4400.0102

4400.0102

Schurter

CIR BRKR THRM 2.8A 240VAC 48VDC

0

4435.0656

4435.0656

Schurter

CBE TA35-C323F160C0

13

4410.0016

4410.0016

Schurter

CIR BRKR THRM 2A 240VAC 28VDC

16

4435.0335

4435.0335

Schurter

CIR BRKR THRM 12A 240VAC 60VDC

6

4435.0216

4435.0216

Schurter

CIR BRKR THRM 3A 240VAC 60VDC

10

3-101-226

3-101-226

Schurter

CIR BRKR THRM 6A 240VAC 48VDC

39

4435.0278

4435.0278

Schurter

CIR BRKR THRM 6A 240VAC 60VDC

0

4435.0566

4435.0566

Schurter

CIR BRKR THRM 7A 240VAC 32VDC

14

4410.9015

4410.9015

Schurter

CIR BRKR THRM 15A 240VAC 28VDC

8

4420.0409

4420.0409

Schurter

CIR BRKR THRM MAG 45A 480V 65V

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure