Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4430.3862

4430.3862

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

15

4420.0808

4420.0808

Schurter

CIR BRKR THRM MAG 15A 360 VDC

0

4430.0847

4430.0847

Schurter

CIR BRKR THRM 5A 240VAC 60VDC

0

4419.9004

4419.9004

Schurter

CIR BRKR THRM 1A 240VAC 48VDC

0

TS-701-HT-8

TS-701-HT-8

Schurter

CIR BRKR THRM 8A 250VAC 50VDC

968200

4435.0018

4435.0018

Schurter

CIR BRKR THRM 240VAC ROCKER

10

3-101-229

3-101-229

Schurter

CIR BRKR THRM 12A 240VAC 48VDC

89

4420.0609

4420.0609

Schurter

CIR BRKR THRM MAG 23A 480V 65V

0

4430.2793

4430.2793

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

11

4435.0241

4435.0241

Schurter

CIR BRKR THRM 10A 240VAC 32VDC

22

4435.0572

4435.0572

Schurter

CIR BRKR THRM 2.5A 240VAC 32VDC

32

4435.0013

4435.0013

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

1007

4430.2977

4430.2977

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

15

4435.0478

4435.0478

Schurter

CIR BRKR THRM 16A 240VAC 32VDC

34

4420.0686

4420.0686

Schurter

CIR BRKR THRM MAG 50A 480V 65V

0

4430.1609

4430.1609

Schurter

CIR BRKR THRM 6A 240VAC 60VDC

0

4420.0287

4420.0287

Schurter

CIR BRKR THRM MAG 30A 480V 65V

8

4400.002

4400.002

Schurter

CIR BRKR THRM 1.2A 240VAC 48VDC

0

4435.0257

4435.0257

Schurter

CIR BRKR THRM 5A 240VAC 32VDC

18

4435.0626

4435.0626

Schurter

CIR BRKR THRM 5A 240VAC 32VDC

8

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure