Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4430.1944

4430.1944

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

6

4435.0209

4435.0209

Schurter

CIR BRKR THRM 16A 240VAC 32VDC

33

4400.0002

4400.0002

Schurter

CIR BRKR THRM 2A 240VAC 48VDC

24

4435.0635

4435.0635

Schurter

CIR BRKR THRM 18A 240VAC 32VDC

3

TS-701-HT-30

TS-701-HT-30

Schurter

CIR BRKR THRM 30A 250VAC 50VDC

200

4435.0151

4435.0151

Schurter

CIR BRKR THRM 20A 240VAC 60VDC

10

4430.1359

4430.1359

Schurter

CIR BRKR THRM 8A 240VAC 60VDC

14

4430.2511

4430.2511

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

0

4430.3874

4430.3874

Schurter

CIR BRKR THRM 7A 240VAC 60VDC

18

4411.0089

4411.0089

Schurter

CIR BRKR THRM 16A 277VAC 28VDC

20

4430.3659

4430.3659

Schurter

CIR BRKR THRM 15A 240VAC 60VDC

0

4400.0279

4400.0279

Schurter

CIR BRKR THRM 12A 240VAC 48VDC

99

4420.0174

4420.0174

Schurter

CIR BRKR THRM MAG 10A 480V 65V

0

4430.2298

4430.2298

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

150

4410.9014

4410.9014

Schurter

CIR BRKR THRM 16A 240VAC 28VDC

20

TS-709-12

TS-709-12

Schurter

CIR BRKR THRM 12A 250VAC 50VDC

101200

4435.0187

4435.0187

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

20

4410.9002

4410.9002

Schurter

CIR BRKR THRM 10A 240VAC 28VDC

8

4400.0512

4400.0512

Schurter

CIR BRKR THRM 13A 240VAC 48VDC

88

4420.0268

4420.0268

Schurter

CIR BRKR THRM MAG 25A 180 VDC

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure