Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
181-44027

181-44027

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

181-00521

181-00521

HellermannTyton

WIRE DUCT SOLID BASE ADH SCRW 6'

0

TSR3W-8A

TSR3W-8A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 8'

0

181-11005

181-11005

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

184-15102

184-15102

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

181-12005

181-12005

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

30

184-15304

184-15304

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

181-45002

181-45002

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

184-15152

184-15152

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

181-00608

181-00608

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

181-00232

181-00232

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

181-15100

181-15100

HellermannTyton

WIRE DUCT SOLID BASE SCRW BLK 6'

0

184-23006

184-23006

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

184-43001

184-43001

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

181-24011

181-24011

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

181-22024

181-22024

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

243

184-32004

184-32004

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

181-15206

181-15206

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

181-00136

181-00136

HellermannTyton

WIRE DUCT SOLID BASE SCRW GRY 6'

20

181-11009

181-11009

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top