Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
TSR1I-8A

TSR1I-8A

HellermannTyton

WIRE DUCT SOLID ADH SCRW IVRY 8'

0

181-12011

181-12011

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW GY 6'

0

181-00170

181-00170

HellermannTyton

WIRE DUCT SOLID BASE SCRW GRY 6'

0

181-22005

181-22005

HellermannTyton

WIRE DUCT SOLID BASE SCRW BLK 6'

0

TSR3FW-6A

TSR3FW-6A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 6'

0

TSRP2W-8A

TSRP2W-8A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 8'

0

181-44019

181-44019

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

181-45010

181-45010

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

181-00585

181-00585

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW GY 6'

18

TSR3FW-8A

TSR3FW-8A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 8'

0

TSRP2FW-6A

TSRP2FW-6A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 6'

0

181-00492

181-00492

HellermannTyton

WIRE DUCT SOLID BASE ADH SCRW 6'

0

181-33021

181-33021

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW GY 6'

0

184-13007

184-13007

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

181-33009

181-33009

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

181-00217

181-00217

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

181-43002

181-43002

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

184-33002

184-33002

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

184-22008

184-22008

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

TSRP3I-6A

TSRP3I-6A

HellermannTyton

WIRE DUCT SOLID ADH SCRW IVRY 6'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top