Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
181-00193

181-00193

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

181-34002

181-34002

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

181-15203

181-15203

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

181-34001

181-34001

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

181-11509

181-11509

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW GY 6'

0

184-15401

184-15401

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

181-11502

181-11502

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

24

184-11009

184-11009

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW WT 6'

0

181-00654

181-00654

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW GY 6'

15

184-14002

184-14002

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

181-24008

181-24008

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

TSR3I-6A

TSR3I-6A

HellermannTyton

WIRE DUCT SOLID ADH SCRW IVRY 6'

0

181-21007

181-21007

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

181-45011

181-45011

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

181-00655

181-00655

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW WT 6'

13

181-33014

181-33014

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

TSRP3W-8A

TSRP3W-8A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 8'

0

181-23002

181-23002

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

181-44033

181-44033

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW GY 6'

0

184-11012

184-11012

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top