Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
1485B36

1485B36

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 3'

0

1485F48

1485F48

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 4'

0

1486D30

1486D30

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTEN 2.5'

0

1486C30

1486C30

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTEN 2.5'

0

1486B60

1486B60

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 5'

0

1486C48

1486C48

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 4'

0

1485D60

1485D60

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 5'

0

1486D12

1486D12

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 1'

0

1486B24

1486B24

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 2'

0

1485E48

1485E48

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 4'

0

1487E60

1487E60

Hammond Manufacturing

WIREWAY PULL THRGH 60" 8X8" GRAY

0

1485D6

1485D6

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTEN 0.50'

0

1485F12

1485F12

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 1'

0

1487D36

1487D36

Hammond Manufacturing

WIREWAY PULL THRGH 36" 6X6" GRAY

0

1487B24

1487B24

Hammond Manufacturing

WIREWAY PULL THRGH 24" 2.5X2.5"

0

1487B120

1487B120

Hammond Manufacturing

WIREWAY PULL THRGH 120" 2.5X2.5"

0

1486B48

1486B48

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 4'

0

1485F6

1485F6

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTEN 0.50'

0

1485E6

1485E6

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTEN 0.50'

0

1487B36

1487B36

Hammond Manufacturing

WIREWAY PULL THRGH 36" 2.5X2.5"

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top