Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
1485E24

1485E24

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 2'

0

1486C72

1486C72

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 6'

0

1485C12

1485C12

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 1'

0

1485E36

1485E36

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 3'

0

1485F36

1485F36

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 3'

0

1487E12

1487E12

Hammond Manufacturing

WIREWAY PULL THRGH 12" 8X8" GRAY

0

1487C12

1487C12

Hammond Manufacturing

WIREWAY PULL THRGH 12" 4X4" GR

0

1486D24

1486D24

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 2'

0

1485E60

1485E60

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 5'

0

1485C24

1485C24

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 2'

0

1486C18

1486C18

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTEN 1.5'

0

1486C24

1486C24

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 2'

0

1486B72

1486B72

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 6'

0

1487E24

1487E24

Hammond Manufacturing

WIREWAY PULL THRGH 24" 8X8" GRAY

0

1487E120

1487E120

Hammond Manufacturing

WIREWAY PULL THRGH 120" 8X8" GRY

0

1485D48

1485D48

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 4'

0

1485B24

1485B24

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 2'

0

1485C60

1485C60

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 5'

0

1485D12

1485D12

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 1'

0

1486D18

1486D18

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTEN 1.5'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top