Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
1486D48

1486D48

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 4'

0

1485C48

1485C48

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 4'

0

1487D120

1487D120

Hammond Manufacturing

WIREWAY PULL THRGH 120" 6X6" GR

0

1485BJ

1485BJ

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 1'

0

CWST696

CWST696

Hammond Manufacturing

COVER HINGED STRAIGHT 6X6X96"

0

CWSC418NK

CWSC418NK

Hammond Manufacturing

COVER SCREW STRAIGHT 4X4X18"

0

1485DZ12

1485DZ12

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 1'

0

1487CT

1487CT

Hammond Manufacturing

WIREWAY TEE FITTING 4X4"

0

CWSC612NK

CWSC612NK

Hammond Manufacturing

COVER SCREW STRAIGHT 6X6X12"

0

CWSC460NK

CWSC460NK

Hammond Manufacturing

COVER SCREW STRAIGHT 4X4X60"

0

CWST1272NK

CWST1272NK

Hammond Manufacturing

COVER HINGED STR 12X12X72"

0

1485CZ12

1485CZ12

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 1'

0

CWST672

CWST672

Hammond Manufacturing

COVER HINGED STRAIGHT 6X6X72"

0

CWSC248NK

CWSC248NK

Hammond Manufacturing

COVER SCREW STR 2.5X2.5X48"

0

CWST1212NK

CWST1212NK

Hammond Manufacturing

COVER HINGED STR 12X12X12"

0

CWSC624NK

CWSC624NK

Hammond Manufacturing

COVER SCREW STRAIGHT 6X6X24"

0

CWST612

CWST612

Hammond Manufacturing

COVER HINGED STRAIGHT 6X6X12"

0

CWST248

CWST248

Hammond Manufacturing

COVER HINGED STR 2.5X2.5X48"

0

CWSC818NK

CWSC818NK

Hammond Manufacturing

COVER SCREW STRAIGHT 8X8X18"

0

CWST648

CWST648

Hammond Manufacturing

COVER HINGED STRAIGHT 6X6X48"

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers