Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
F1.5X3WH6

F1.5X3WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

328080

181-15100

181-15100

HellermannTyton

WIRE DUCT SOLID BASE SCRW BLK 6'

0

F.5X.5WH6

F.5X.5WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

4972

184-23006

184-23006

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

G1.5X2LG6

G1.5X2LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

29

F2X1LG6-A

F2X1LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

20

F2X2LG6-A

F2X2LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

15144

3240283

3240283

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

9

F1X1LG6

F1X1LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

799372

G2X3WH6

G2X3WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

115972

HS4X4LG6NM

HS4X4LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

2460

F2X2WH6

F2X2WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

23396

3240195

3240195

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

2

LD5IW6-A

LD5IW6-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE WHT 6'

2015072

H3X3LG6

H3X3LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

1

FS1.5X3LG6NM

FS1.5X3LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

0

FS3X3WH6NM

FS3X3WH6NM

Panduit Corporation

WIRE DUCT SOLID BASE WHITE 6'

9

1486B48

1486B48

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 4'

0

184-43001

184-43001

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

G2X3LG6

G2X3LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

9024

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top