Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
SG4040-BOX

SG4040-BOX

Tecnomatic Corp

SMALL FINGER GRAY DUCT 1&1/2 X 1

3

184-33002

184-33002

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

F6X4LG6

F6X4LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

26534

FS1.5X2LG6

FS1.5X2LG6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW GRY 6'

18

F4X3WH6

F4X3WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

20

LDPH3IW8-A

LDPH3IW8-A

Panduit Corporation

WIRE DUCT SOLID 2PC ADH SCREW 8'

0

F2X4IB6

F2X4IB6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLUE 6'

18

LDPH5WH6-A

LDPH5WH6-A

Panduit Corporation

WIRE DUCT SOLID 2PC ADH SCREW 6'

23

184-22008

184-22008

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

1485F12

1485F12

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 1'

0

TSRP3I-6A

TSRP3I-6A

HellermannTyton

WIRE DUCT SOLID ADH SCRW IVRY 6'

0

181-44027

181-44027

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

181-00521

181-00521

HellermannTyton

WIRE DUCT SOLID BASE ADH SCRW 6'

0

WG30EZ10

WG30EZ10

Panduit Corporation

PATHWAY 30 WX10' L ELECTRO

260

G.75X2LG6-A

G.75X2LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

383906

TSR3W-8A

TSR3W-8A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 8'

0

1487D36

1487D36

Hammond Manufacturing

WIREWAY PULL THRGH 36" 6X6" GRAY

0

MC25X25IG2

MC25X25IG2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

0

3240282

3240282

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

4192

181-11005

181-11005

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers