Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
G1.5X1LG6-A

G1.5X1LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

1990

184-15102

184-15102

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

G1X1BL6

G1X1BL6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLACK 6'

302102

AG4060-BOX

AG4060-BOX

Tecnomatic Corp

WIDE FINGER GRAY DUCT 1&1/2 X 2&

1

FS2X3WH6NM

FS2X3WH6NM

Panduit Corporation

WIRE DUCT SOLID BASE WHITE 6'

7

1487B24

1487B24

Hammond Manufacturing

WIREWAY PULL THRGH 24" 2.5X2.5"

0

181-12005

181-12005

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

30

1487B120

1487B120

Hammond Manufacturing

WIREWAY PULL THRGH 120" 2.5X2.5"

0

184-15304

184-15304

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

G1.5X1.5WH6

G1.5X1.5WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

25

LD10WH10-A

LD10WH10-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE WHT 10'

19917600

HN2X3LG6

HN2X3LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

2

F1.5X2WH6

F1.5X2WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

41834

181-45002

181-45002

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

RX4040-0

RX4040-0

Richco, Inc. (Essentra Components)

WIRE DUCT FLEX SCREW GRAY 1.64'

455

184-15152

184-15152

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

181-00608

181-00608

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

181-00232

181-00232

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

SCD-2228

SCD-2228

Richco, Inc. (Essentra Components)

WIRE DUCT SOLID BASE ADHESIVE 6'

10

H2X2LG6

H2X2LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

8

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top