Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
T70BIW10

T70BIW10

Panduit Corporation

WIRE DUCT SOLID BASE SCREW 10'

504680

181-22019

181-22019

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

181-11015

181-11015

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

8

T45BEI8-A

T45BEI8-A

Panduit Corporation

WIRE DUCT SOLID BASE ADH 8'

0

3240200

3240200

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

27606

G2X4WH6

G2X4WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

22

FS1.5X2LG6NM

FS1.5X2LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

15

TSR2I-8A

TSR2I-8A

HellermannTyton

WIRE DUCT SOLID ADH SCRW IVRY 8'

0

SG10060-BOX

SG10060-BOX

Tecnomatic Corp

SMALL FINGER GRAY DUCT 4 X 2&1/

2

3240636

3240636

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

396

FS2X4LG6NM

FS2X4LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

6906

FWF-14111

FWF-14111

Quest Technology International

RACEWAY ONAROLL 3/8'' WHT 100 F

0

F2X2LG6

F2X2LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

16013314

G2.5X3LG6

G2.5X3LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

18948

F1.5X1.5WH6

F1.5X1.5WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

59360

F1.5X1WH6

F1.5X1WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

17

FS2X1.5LG6

FS2X1.5LG6

Panduit Corporation

EUROPEAN STYLE DUCT 6'

90

N080-D25-2M-WH

N080-D25-2M-WH

Tripp Lite

WIRE DUCT SOLID 2PC ADH WT 6.56'

461

1486C18

1486C18

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTEN 1.5'

0

181-11000

181-11000

HellermannTyton

WIRE DUCT SOLID BASE SCRW BLK 6'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top