Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
LDPH10EI8-A

LDPH10EI8-A

Panduit Corporation

WIRE DUCT SOLID 2PC ADH SCRW 8'

0

G.5X2WH6

G.5X2WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

30270

G1X3LG6-A

G1X3LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

13312

181-00249

181-00249

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

FRHD2KTBL

FRHD2KTBL

Panduit Corporation

WIRE DUCT SLOTTED 2PC BRKT MT 6'

0

SG60100-BOX

SG60100-BOX

Tecnomatic Corp

SMALL FINGER GRAY DUCT 2&1/4 X 4

3

1486C24

1486C24

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 2'

0

G2X1BL6

G2X1BL6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLACK 6'

48

1486B72

1486B72

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 6'

0

G1.5X1WH6

G1.5X1WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

20

181-22034

181-22034

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW WT 6'

0

181-15306

181-15306

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

184-24007

184-24007

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

RX2020-4

RX2020-4

Richco, Inc. (Essentra Components)

WIRE DUCT FLEXIBLE ADH GRY 1.64'

61

251-30409

251-30409

HellermannTyton

FTD GROMMET PTFE 3M/RL

2

AG4040-BOX

AG4040-BOX

Tecnomatic Corp

WIDE FINGER GRAY DUCT 1&1/2 X 1&

0

FWF-25121

FWF-25121

Quest Technology International

RACEWAY ONAROLL 1/4'' BEIGE 100

47

F4X4LG6-A

F4X4LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

9120

TSRP1W-8A

TSRP1W-8A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 8'

0

G1X2BL6

G1X2BL6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLACK 6'

201116

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers