Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
AG4080-BOX

AG4080-BOX

Tecnomatic Corp

WIDE FINGER GRAY DUCT 1&1/2 X 3

2

NE1.5X1.5WH6

NE1.5X1.5WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

37

181-00560

181-00560

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

G2X2LG6-A

G2X2LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

53630

T45BIW10-A

T45BIW10-A

Panduit Corporation

WIRE DUCT SOLID BASE ADH WHT 10'

0

F3X5BL6

F3X5BL6

Panduit Corporation

NARROW SLOTTED DUCT, PVC, 3" X 5

10

F3X2LG6

F3X2LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

171800

184-22005

184-22005

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

181-23004

181-23004

HellermannTyton

WIRE DUCT SLOTTED SCREW BLUE 6'

0

F3X4BL6

F3X4BL6

Panduit Corporation

NARROW SLOTTED DUCT, PVC, 3" X 4

9

181-32003

181-32003

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

181-00595

181-00595

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW BK 6'

0

AG2560-BOX

AG2560-BOX

Tecnomatic Corp

WIDE FINGER GRAY DUCT 1X2&1/4

3

TSRP2W-6A

TSRP2W-6A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 6'

0

FWF-14511

FWF-14511

Quest Technology International

RACEWAY ONAROLL 3/8'' WHT 50 FT

5

G.5X1WH6

G.5X1WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

1166

AG2540-BOX

AG2540-BOX

Tecnomatic Corp

WIDE FINGER GRAY DUCT 1X1&1/2

0

181-42005

181-42005

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

G1X4WH6-A

G1X4WH6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

1224

3240361

3240361

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers