Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
LD5WH6-A

LD5WH6-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE WHT 6'

3653880

3240348

3240348

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

76

TNC37X37LG2

TNC37X37LG2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

1860

181-32005

181-32005

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

NE1X1WH6

NE1X1WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

333774

1485E60

1485E60

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 5'

0

3240305

3240305

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

0

G2X3LG6EMI

G2X3LG6EMI

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

11

FS.5X.5WH6NM

FS.5X.5WH6NM

Panduit Corporation

WIRE DUCT SOLID BASE WHITE 6'

34

181-45001

181-45001

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

3240280

3240280

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

75384

G3X4WH6

G3X4WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

3

F2X1.5WH6

F2X1.5WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

1996

H1.5X2LG6

H1.5X2LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

79348

TSRP3FW-8A

TSRP3FW-8A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 8'

0

181-15107

181-15107

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

7

HN1.5X3WH6

HN1.5X3WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

0

F1X2LG6-A

F1X2LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

44848

TSR1W-6A

TSR1W-6A

HellermannTyton

WIRE DUCT SOLID ADH SCREW WHT 6'

0

181-44020

181-44020

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers