Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
G4X4WH6-A

G4X4WH6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

612

F4X5WH6

F4X5WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

301830

3240346

3240346

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

4

181-11505

181-11505

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

LDPH5EI8-A

LDPH5EI8-A

Panduit Corporation

WIRE DUCT SOLID 2PC ADH SCREW 8'

20

TSR2I-6A

TSR2I-6A

HellermannTyton

WIRE DUCT SOLID ADH SCRW IVRY 6'

0

3240197

3240197

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

531380

F1X4IB6

F1X4IB6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLUE 6'

16

181-11503

181-11503

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

F.5X.5LG6

F.5X.5LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

18

TSR3I-8A

TSR3I-8A

HellermannTyton

WIRE DUCT SOLID ADH SCRW IVRY 8'

0

1485E12

1485E12

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 1'

0

LD3WH10-A

LD3WH10-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE WHT 10'

8400

G2X2LG6

G2X2LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

7630942

F1X4LG6-A

F1X4LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

748

G.75X.75LG6-A

G.75X.75LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

12456

181-15500

181-15500

HellermannTyton

WIRE DUCT SOLID BASE SCRW BLK 6'

0

1485F60

1485F60

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 5'

0

184-14004

184-14004

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

G1X1LG6

G1X1LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

2359216

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email
Top