Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
G.5X2LG6

G.5X2LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

394746

FWH-11414

FWH-11414

Quest Technology International

WIREHIDER RACEWAY 1/2'' WHT 4FT

840

3240201

3240201

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

198

F2X3WH6

F2X3WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

93186

184-32001

184-32001

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

TNC100X50LG2

TNC100X50LG2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

0

LD5IW10-A

LD5IW10-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE WHT 10'

2005800

FS.5X1LG6

FS.5X1LG6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW GRY 6'

2018

1486D60

1486D60

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 5'

0

181-11019

181-11019

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW GY 6'

0

3240311

3240311

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

2

181-11501

181-11501

HellermannTyton

WIRE DUCT SOLID BASE SCRW GRY 6'

0

FS1.5X1.5WH6

FS1.5X1.5WH6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW WHT 6'

1930

181-00578

181-00578

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW WT 6'

20

181-00558

181-00558

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

FS2X1.5LG6NM

FS2X1.5LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

30660

3240187

3240187

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

2201275

G.5X4LG6

G.5X4LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

7

181-00176

181-00176

HellermannTyton

WIRE DUCT SOLID BASE SCRW GRY 6'

0

G2X1.5WH6

G2X1.5WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

18

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers