Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
F1.5X2LG6

F1.5X2LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

20

F1X1BL6

F1X1BL6

Panduit Corporation

NARROW SLOTTED DUCT, PVC, 1" X 1

20

184-15206

184-15206

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

FS1X2LG6NM

FS1X2LG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

2090

181-00554

181-00554

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

16

181-00193

181-00193

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

SG8060-BOX

SG8060-BOX

Tecnomatic Corp

SMALL FINGER GRAY DUCT 3 X 2&1/4

2

181-34002

181-34002

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

T45BEI8

T45BEI8

Panduit Corporation

WIRE DUCT SOLID BASE SCREW 8'

0

181-15203

181-15203

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

H4X4LG6

H4X4LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

19

RX3030-4

RX3030-4

Richco, Inc. (Essentra Components)

WIRE DUCT FLEXIBLE ADH GRY 1.64'

108

G1X4BL6

G1X4BL6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLACK 6'

1030

181-34001

181-34001

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

RX3030-0

RX3030-0

Richco, Inc. (Essentra Components)

WIRE DUCT FLEX SCREW GRAY 1.64'

40

FS1X1.5LG6

FS1X1.5LG6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW GRY 6'

7

1486C12

1486C12

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 1'

0

WG30BL10

WG30BL10

Panduit Corporation

PATHWAY 30 WX10' L BLACK P

1560

LD3WH6-A

LD3WH6-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE WHT 6'

6121788

DRD44LG6

DRD44LG6

Panduit Corporation

WIRE DUCT SLOTTED DIN RL FAST 6'

33

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers