Power Transformers

Image Part Number Description / PDF Quantity Rfq
R8303NL

R8303NL

PulseR (iNRCORE

TRANSFORMER PLANAR 240UH

0

R8234NL

R8234NL

PulseR (iNRCORE

TRANSFORMER PLANAR 54UH

0

R8301NLT

R8301NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 153UH

0

R8242NLT

R8242NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 54UH

0

R8232NLT

R8232NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 120UH

0

R8208NLT

R8208NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 216UH

0

R8239NL

R8239NL

PulseR (iNRCORE

TRANSFORMER PLANAR 85UH

0

R8235NL

R8235NL

PulseR (iNRCORE

TRANSFORMER PLANAR 85UH

0

R8203NL

R8203NL

PulseR (iNRCORE

TRANSFORMER PLANAR 340UH

0

R8240NLT

R8240NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 120UH

0

R8233NLT

R8233NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 165UH

0

R8241NL

R8241NL

PulseR (iNRCORE

TRANSFORMER PLANAR 165UH

0

R8310NL

R8310NL

PulseR (iNRCORE

TRANSFORMER PLANAR 345UH

0

R8401NLT

R8401NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 211UH

0

R8410NLT

R8410NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 768UH

0

R8249NLT

R8249NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 215UH

0

R8407NL

R8407NL

PulseR (iNRCORE

TRANSFORMER PLANAR 330UH

0

R8249NL

R8249NL

PulseR (iNRCORE

TRANSFORMER PLANAR 215UH

0

R8230NL

R8230NL

PulseR (iNRCORE

TRANSFORMER PLANAR 54UH

0

R8403NLT

R8403NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 423UH

0

Power Transformers

1. Overview

Power transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. They enable voltage conversion (step-up/step-down) while maintaining galvanic isolation. These components are fundamental in power distribution systems, renewable energy integration, and industrial equipment, ensuring efficient energy transmission and voltage level adaptation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Distribution TransformersMedium voltage conversion (1kV-36kV), compact designUrban power grids, residential areas
Transmission TransformersHigh voltage (66kV-800kV), grid stability focusSubstations, long-distance power lines
Instrument TransformersMeasurement and protection (CT/VT types)Energy metering, relay protection
Specialty TransformersCustom configurations (furnace, traction, marine)Industrial furnaces, railway systems

3. Structure and Components

Typical construction includes:

  • Core: Grain-oriented silicon steel laminations for magnetic flux path
  • Windings: Primary/secondary copper/aluminum coils with insulation layers
  • Insulation: Mineral oil, synthetic esters, or solid materials (e.g., epoxy)
  • Cooling System: Radiator tanks, fans, or forced-oil circulation
  • Tap Changer: On-load/off-load voltage regulation mechanism
  • Protection: Buchholz relay, pressure relief valves, temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Rated Voltage230V-800kVDetermines system compatibility
Power Capacity50kVA-1000MVADefines energy throughput
Voltage Ratio1:1 to 1:20Specifies transformation ratio
Efficiency95%-99.5%Impacts operational costs
Short Circuit Impedance4%-20%Affects fault current limitation
Insulation ClassA (105 C) to C (220 C)Determines thermal endurance

5. Application Areas

Major sectors include:

  • Electricity distribution networks (urban/rural)
  • Renewable energy systems (wind/solar grid-tied inverters)
  • Industrial machinery (CNC, smelters, compressors)
  • Railway traction systems (15kV-25kV conversion)
  • Data centers (HVDC conversion systems)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens EnergyBlue TransformersEnvironmentally friendly synthetic ester insulation
Asea Brown Boveri (ABB)550kV UHV Transformer 500kV DC transmission capability
General Electric (GE)Premier SeriesSmart monitoring with Predictivity analytics
Mitsubishi Electric330MVA Traction TransformerCompact design for Shinkansen trains

7. Selection Guidelines

Key considerations:

  • Voltage levels (primary/secondary requirements)
  • Load profile (continuous vs. intermittent duty)
  • Cooling requirements (ONAN/ONAF/OFAF modes)
  • Environmental conditions (temperature, altitude, seismic zones)
  • Protection features (IP rating, fire resistance)
  • Smart grid compatibility (IoT sensor integration)

Case Study: Wind farm grid connection selected 33/132kV ONAF-cooled transformer with 12% impedance to meet fault ride-through requirements.

8. Industry Trends

Current development directions:

  • Smart transformers with real-time monitoring (IEEE C57.163 compliant)
  • Amorphous metal core adoption (50% core loss reduction)
  • Hydrogen-cooled systems for offshore applications
  • Modular solid-state transformer (SST) prototypes (DOE GRID DATA initiative)
  • Increased demand for 132kV+ mobile transformers in disaster recovery

Market forecasts indicate 6.2% CAGR through 2030, driven by grid modernization and EV charging infrastructure expansion.