Power Transformers

Image Part Number Description / PDF Quantity Rfq
R8409NL

R8409NL

PulseR (iNRCORE

TRANSFORMER PLANAR 588UH

0

R8243NL

R8243NL

PulseR (iNRCORE

TRANSFORMER PLANAR 85UH

0

R8236NLT

R8236NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 120UH

0

R8243NLT

R8243NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 85UH

0

R8203NLT

R8203NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 340UH

0

R8302NL

R8302NL

PulseR (iNRCORE

TRANSFORMER PLANAR 194UH

0

R8315NLT

R8315NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 345UH

0

R8313NL

R8313NL

PulseR (iNRCORE

TRANSFORMER PLANAR 240UH

0

R8404NLT

R8404NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 588UH

0

R8315NL

R8315NL

PulseR (iNRCORE

TRANSFORMER PLANAR 345UH

0

R8232NL

R8232NL

PulseR (iNRCORE

TRANSFORMER PLANAR 120UH

0

R8401NL

R8401NL

PulseR (iNRCORE

TRANSFORMER PLANAR 211UH

0

R8212NLT

R8212NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 480UH

0

R8245NLT

R8245NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 165UH

0

R8231NLT

R8231NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 85UH

0

R8308NL

R8308NL

PulseR (iNRCORE

TRANSFORMER PLANAR 240UH

0

R8231NL

R8231NL

PulseR (iNRCORE

TRANSFORMER PLANAR 85UH

0

R8214NL

R8214NL

PulseR (iNRCORE

TRANSFORMER PLANAR 660UH

0

R8309NLT

R8309NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 290UH

0

R8214NLT

R8214NLT

PulseR (iNRCORE

TRANSFORMER PLANAR 660UH

0

Power Transformers

1. Overview

Power transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. They enable voltage conversion (step-up/step-down) while maintaining galvanic isolation. These components are fundamental in power distribution systems, renewable energy integration, and industrial equipment, ensuring efficient energy transmission and voltage level adaptation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Distribution TransformersMedium voltage conversion (1kV-36kV), compact designUrban power grids, residential areas
Transmission TransformersHigh voltage (66kV-800kV), grid stability focusSubstations, long-distance power lines
Instrument TransformersMeasurement and protection (CT/VT types)Energy metering, relay protection
Specialty TransformersCustom configurations (furnace, traction, marine)Industrial furnaces, railway systems

3. Structure and Components

Typical construction includes:

  • Core: Grain-oriented silicon steel laminations for magnetic flux path
  • Windings: Primary/secondary copper/aluminum coils with insulation layers
  • Insulation: Mineral oil, synthetic esters, or solid materials (e.g., epoxy)
  • Cooling System: Radiator tanks, fans, or forced-oil circulation
  • Tap Changer: On-load/off-load voltage regulation mechanism
  • Protection: Buchholz relay, pressure relief valves, temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Rated Voltage230V-800kVDetermines system compatibility
Power Capacity50kVA-1000MVADefines energy throughput
Voltage Ratio1:1 to 1:20Specifies transformation ratio
Efficiency95%-99.5%Impacts operational costs
Short Circuit Impedance4%-20%Affects fault current limitation
Insulation ClassA (105 C) to C (220 C)Determines thermal endurance

5. Application Areas

Major sectors include:

  • Electricity distribution networks (urban/rural)
  • Renewable energy systems (wind/solar grid-tied inverters)
  • Industrial machinery (CNC, smelters, compressors)
  • Railway traction systems (15kV-25kV conversion)
  • Data centers (HVDC conversion systems)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens EnergyBlue TransformersEnvironmentally friendly synthetic ester insulation
Asea Brown Boveri (ABB)550kV UHV Transformer 500kV DC transmission capability
General Electric (GE)Premier SeriesSmart monitoring with Predictivity analytics
Mitsubishi Electric330MVA Traction TransformerCompact design for Shinkansen trains

7. Selection Guidelines

Key considerations:

  • Voltage levels (primary/secondary requirements)
  • Load profile (continuous vs. intermittent duty)
  • Cooling requirements (ONAN/ONAF/OFAF modes)
  • Environmental conditions (temperature, altitude, seismic zones)
  • Protection features (IP rating, fire resistance)
  • Smart grid compatibility (IoT sensor integration)

Case Study: Wind farm grid connection selected 33/132kV ONAF-cooled transformer with 12% impedance to meet fault ride-through requirements.

8. Industry Trends

Current development directions:

  • Smart transformers with real-time monitoring (IEEE C57.163 compliant)
  • Amorphous metal core adoption (50% core loss reduction)
  • Hydrogen-cooled systems for offshore applications
  • Modular solid-state transformer (SST) prototypes (DOE GRID DATA initiative)
  • Increased demand for 132kV+ mobile transformers in disaster recovery

Market forecasts indicate 6.2% CAGR through 2030, driven by grid modernization and EV charging infrastructure expansion.

RFQ BOM Call Skype Email