Power Transformers

Image Part Number Description / PDF Quantity Rfq
VPM12-2080

VPM12-2080

Triad Magnetics

PWR XFMR TORO 25VA CHAS MT

14111

FD4-56

FD4-56

Triad Magnetics

PWR XFMR LAMINATED 6VA CHAS MT

17

VPL28-2000

VPL28-2000

Triad Magnetics

PWR XFMR LAMINATED 56.0VA CHAS

72549

F-119X

F-119X

Triad Magnetics

PWR XFMR LAMINATED 4.02VA CHAS

0

F-268U

F-268U

Triad Magnetics

PWR XFMR LAMINATED 280VA CHAS MT

9

F-193U

F-193U

Triad Magnetics

PWR XFMR LAMINATED 96VA CHAS MT

0

F12-090

F12-090

Triad Magnetics

PWR XFMR LAMINATED 1.1VA TH

1353

FS16-1250

FS16-1250

Triad Magnetics

PWR XFMR LAMINATED 20VA TH

181

VPL36-700

VPL36-700

Triad Magnetics

PWR XFMR LAMINATED 25.0VA CHAS

68180

VPM36-4440

VPM36-4440

Triad Magnetics

PWR XFMR TORO 160VA CHAS MT

11

FP30-800

FP30-800

Triad Magnetics

PWR XFMR LAMINATED 24VA TH

43

F-113X

F-113X

Triad Magnetics

PWR XFMR LAMINATED 1.8VA CHAS MT

63

VPM240-420

VPM240-420

Triad Magnetics

PWR XFMR TORO 100VA CHAS MT

0

F56-650

F56-650

Triad Magnetics

PWR XFMR LAMINATED 36VA TH

100

F-244U

F-244U

Triad Magnetics

PWR XFMR LAMINATED 288VA CHAS MT

139

F-349XP

F-349XP

Triad Magnetics

PWR XFMR LAMINATED 4.5VA TH

12

VPP20-1500-B

VPP20-1500-B

Triad Magnetics

PWR XFMR LAMINATED 30VA TH

0

FP24-500

FP24-500

Triad Magnetics

PWR XFMR LAMINATED 12VA TH

4

F12-200

F12-200

Triad Magnetics

PWR XFMR LAMINATED 2.5VA TH

7

F36-350

F36-350

Triad Magnetics

PWR XFMR LAMINATED 12VA TH

0

Power Transformers

1. Overview

Power transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. They enable voltage conversion (step-up/step-down) while maintaining galvanic isolation. These components are fundamental in power distribution systems, renewable energy integration, and industrial equipment, ensuring efficient energy transmission and voltage level adaptation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Distribution TransformersMedium voltage conversion (1kV-36kV), compact designUrban power grids, residential areas
Transmission TransformersHigh voltage (66kV-800kV), grid stability focusSubstations, long-distance power lines
Instrument TransformersMeasurement and protection (CT/VT types)Energy metering, relay protection
Specialty TransformersCustom configurations (furnace, traction, marine)Industrial furnaces, railway systems

3. Structure and Components

Typical construction includes:

  • Core: Grain-oriented silicon steel laminations for magnetic flux path
  • Windings: Primary/secondary copper/aluminum coils with insulation layers
  • Insulation: Mineral oil, synthetic esters, or solid materials (e.g., epoxy)
  • Cooling System: Radiator tanks, fans, or forced-oil circulation
  • Tap Changer: On-load/off-load voltage regulation mechanism
  • Protection: Buchholz relay, pressure relief valves, temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Rated Voltage230V-800kVDetermines system compatibility
Power Capacity50kVA-1000MVADefines energy throughput
Voltage Ratio1:1 to 1:20Specifies transformation ratio
Efficiency95%-99.5%Impacts operational costs
Short Circuit Impedance4%-20%Affects fault current limitation
Insulation ClassA (105 C) to C (220 C)Determines thermal endurance

5. Application Areas

Major sectors include:

  • Electricity distribution networks (urban/rural)
  • Renewable energy systems (wind/solar grid-tied inverters)
  • Industrial machinery (CNC, smelters, compressors)
  • Railway traction systems (15kV-25kV conversion)
  • Data centers (HVDC conversion systems)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens EnergyBlue TransformersEnvironmentally friendly synthetic ester insulation
Asea Brown Boveri (ABB)550kV UHV Transformer 500kV DC transmission capability
General Electric (GE)Premier SeriesSmart monitoring with Predictivity analytics
Mitsubishi Electric330MVA Traction TransformerCompact design for Shinkansen trains

7. Selection Guidelines

Key considerations:

  • Voltage levels (primary/secondary requirements)
  • Load profile (continuous vs. intermittent duty)
  • Cooling requirements (ONAN/ONAF/OFAF modes)
  • Environmental conditions (temperature, altitude, seismic zones)
  • Protection features (IP rating, fire resistance)
  • Smart grid compatibility (IoT sensor integration)

Case Study: Wind farm grid connection selected 33/132kV ONAF-cooled transformer with 12% impedance to meet fault ride-through requirements.

8. Industry Trends

Current development directions:

  • Smart transformers with real-time monitoring (IEEE C57.163 compliant)
  • Amorphous metal core adoption (50% core loss reduction)
  • Hydrogen-cooled systems for offshore applications
  • Modular solid-state transformer (SST) prototypes (DOE GRID DATA initiative)
  • Increased demand for 132kV+ mobile transformers in disaster recovery

Market forecasts indicate 6.2% CAGR through 2030, driven by grid modernization and EV charging infrastructure expansion.

RFQ BOM Call Skype Email
Top