Power Transformers

Image Part Number Description / PDF Quantity Rfq
VPM48-5200

VPM48-5200

Triad Magnetics

PWR XFMR TORO 250VA CHAS MT

28

VPS24-1000

VPS24-1000

Triad Magnetics

PWR XFMR LAMINATED 25VA CHAS MT

5703

F-70X

F-70X

Triad Magnetics

PWR XFMR LAMINATED 12.6VA CHAS

25

FS12-500-C2

FS12-500-C2

Triad Magnetics

PWR XFMR LAMINATED 6VA TH

247

F-255X

F-255X

Triad Magnetics

PWR XFMR LAMINATED 40VA CHAS MT

1060

F28-700

F28-700

Triad Magnetics

PWR XFMR LAMINATED 20VA TH

0

FS12-1000-C2

FS12-1000-C2

Triad Magnetics

PWR XFMR LAMINATED 12VA TH

1226

VPM18-2780

VPM18-2780

Triad Magnetics

PWR XFMR TORO 50VA CHAS MT

41

VPP12-4400-B

VPP12-4400-B

Triad Magnetics

PWR XFMR LAMINATED 56VA TH

0

F-114X

F-114X

Triad Magnetics

PWR XFMR LAMINATED 8.4VA CHAS MT

4129

FS120-160

FS120-160

Triad Magnetics

PWR XFMR LAMINATED 20VA TH

0

TCT3-11E07AE

TCT3-11E07AE

Triad Magnetics

PWR XFMR LAMINATED 2.5VA CHAS MT

1619540

F28-85

F28-85

Triad Magnetics

PWR XFMR LAMINATED 2.5VA TH

144

F-196U

F-196U

Triad Magnetics

PWR XFMR LAMINATED 63VA CHAS MT

355

VPL20-250

VPL20-250

Triad Magnetics

PWR XFMR LAMINATED 5.0VA CHAS MT

17146

F24-800-C2

F24-800-C2

Triad Magnetics

PWR XFMR LAMINATED 20VA TH

33

VPP10-1000-B

VPP10-1000-B

Triad Magnetics

PWR XFMR LAMINATED 10VA TH

0

TCT40-08E07AE

TCT40-08E07AE

Triad Magnetics

PWR XFMR LAMINATED 40VA CHAS MT

89

F-191U

F-191U

Triad Magnetics

PWR XFMR LAMINATED 140VA CHAS MT

180

VPM240-670

VPM240-670

Triad Magnetics

PWR XFMR TORO 160VA CHAS MT

1110

Power Transformers

1. Overview

Power transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. They enable voltage conversion (step-up/step-down) while maintaining galvanic isolation. These components are fundamental in power distribution systems, renewable energy integration, and industrial equipment, ensuring efficient energy transmission and voltage level adaptation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Distribution TransformersMedium voltage conversion (1kV-36kV), compact designUrban power grids, residential areas
Transmission TransformersHigh voltage (66kV-800kV), grid stability focusSubstations, long-distance power lines
Instrument TransformersMeasurement and protection (CT/VT types)Energy metering, relay protection
Specialty TransformersCustom configurations (furnace, traction, marine)Industrial furnaces, railway systems

3. Structure and Components

Typical construction includes:

  • Core: Grain-oriented silicon steel laminations for magnetic flux path
  • Windings: Primary/secondary copper/aluminum coils with insulation layers
  • Insulation: Mineral oil, synthetic esters, or solid materials (e.g., epoxy)
  • Cooling System: Radiator tanks, fans, or forced-oil circulation
  • Tap Changer: On-load/off-load voltage regulation mechanism
  • Protection: Buchholz relay, pressure relief valves, temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Rated Voltage230V-800kVDetermines system compatibility
Power Capacity50kVA-1000MVADefines energy throughput
Voltage Ratio1:1 to 1:20Specifies transformation ratio
Efficiency95%-99.5%Impacts operational costs
Short Circuit Impedance4%-20%Affects fault current limitation
Insulation ClassA (105 C) to C (220 C)Determines thermal endurance

5. Application Areas

Major sectors include:

  • Electricity distribution networks (urban/rural)
  • Renewable energy systems (wind/solar grid-tied inverters)
  • Industrial machinery (CNC, smelters, compressors)
  • Railway traction systems (15kV-25kV conversion)
  • Data centers (HVDC conversion systems)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens EnergyBlue TransformersEnvironmentally friendly synthetic ester insulation
Asea Brown Boveri (ABB)550kV UHV Transformer 500kV DC transmission capability
General Electric (GE)Premier SeriesSmart monitoring with Predictivity analytics
Mitsubishi Electric330MVA Traction TransformerCompact design for Shinkansen trains

7. Selection Guidelines

Key considerations:

  • Voltage levels (primary/secondary requirements)
  • Load profile (continuous vs. intermittent duty)
  • Cooling requirements (ONAN/ONAF/OFAF modes)
  • Environmental conditions (temperature, altitude, seismic zones)
  • Protection features (IP rating, fire resistance)
  • Smart grid compatibility (IoT sensor integration)

Case Study: Wind farm grid connection selected 33/132kV ONAF-cooled transformer with 12% impedance to meet fault ride-through requirements.

8. Industry Trends

Current development directions:

  • Smart transformers with real-time monitoring (IEEE C57.163 compliant)
  • Amorphous metal core adoption (50% core loss reduction)
  • Hydrogen-cooled systems for offshore applications
  • Modular solid-state transformer (SST) prototypes (DOE GRID DATA initiative)
  • Increased demand for 132kV+ mobile transformers in disaster recovery

Market forecasts indicate 6.2% CAGR through 2030, driven by grid modernization and EV charging infrastructure expansion.

RFQ BOM Call Skype Email
Top