Power Transformers

Image Part Number Description / PDF Quantity Rfq
DPC-120-8

DPC-120-8

Signal Transformer

PWR XFMR LAMINATED 1VA TH

2

F-301X

F-301X

Triad Magnetics

PWR XFMR LAMINATED 7.5VA CHAS MT

7295

TCT40-08E07AB

TCT40-08E07AB

Triad Magnetics

PWR XFMR LAMINATED 40VA CHAS MT

35

L01-6355

L01-6355

Amgis

PWR XFMR TORO 15VA TH

21

F-105Z

F-105Z

Triad Magnetics

PWR XFMR LAMINATED 12VA CHAS MT

101

185E12

185E12

Hammond Manufacturing

XFRMR LAMINATED 80VA CHAS MOUNT

7

TCT40-08E07K

TCT40-08E07K

Triad Magnetics

PWR XFMR LAMINATED 40VA CHAS MT

86

PL10-36-130B

PL10-36-130B

Tamura

PWR XFMR LAMINATED 10VA TH

0

166M25

166M25

Hammond Manufacturing

PWR XFMR LAMINATED 75VA CHAS MT

15

278X

278X

Hammond Manufacturing

PWR XFMR LAMINATED 229VA CHAS MT

3

160F120

160F120

Hammond Manufacturing

PWR XFMR LAMINATED 4.4VA TH

47

1182S12

1182S12

Hammond Manufacturing

PWR XFMR TORO 225VA CHAS MT

40

A41-175-16L

A41-175-16L

Signal Transformer

PWR XFMR LAMINATED 175VA CHAS MT

0

DP-241-6-10

DP-241-6-10

Signal Transformer

PWR XFMR LAMINATED 30VA CHAS MT

0

AHI02520

AHI02520

Zettler Magnetics

PWR XFMR LAMINATED 2.5VA TH

30

1182T60

1182T60

Hammond Manufacturing

PWR XFMR TORO 1500VA CHAS MT

1

L01-6350

L01-6350

Amgis

PWR XFMR TORO 15VA TH

22

302AX

302AX

Hammond Manufacturing

PWR XFMR LAMINATED 198VA CHAS MT

1

F-3185U

F-3185U

Triad Magnetics

PWR XFMR LAMINATED 56VA CHAS MT

584

DST-4-12

DST-4-12

Signal Transformer

PWR XFMR LAMINATED 6VA TH

199

Power Transformers

1. Overview

Power transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. They enable voltage conversion (step-up/step-down) while maintaining galvanic isolation. These components are fundamental in power distribution systems, renewable energy integration, and industrial equipment, ensuring efficient energy transmission and voltage level adaptation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Distribution TransformersMedium voltage conversion (1kV-36kV), compact designUrban power grids, residential areas
Transmission TransformersHigh voltage (66kV-800kV), grid stability focusSubstations, long-distance power lines
Instrument TransformersMeasurement and protection (CT/VT types)Energy metering, relay protection
Specialty TransformersCustom configurations (furnace, traction, marine)Industrial furnaces, railway systems

3. Structure and Components

Typical construction includes:

  • Core: Grain-oriented silicon steel laminations for magnetic flux path
  • Windings: Primary/secondary copper/aluminum coils with insulation layers
  • Insulation: Mineral oil, synthetic esters, or solid materials (e.g., epoxy)
  • Cooling System: Radiator tanks, fans, or forced-oil circulation
  • Tap Changer: On-load/off-load voltage regulation mechanism
  • Protection: Buchholz relay, pressure relief valves, temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Rated Voltage230V-800kVDetermines system compatibility
Power Capacity50kVA-1000MVADefines energy throughput
Voltage Ratio1:1 to 1:20Specifies transformation ratio
Efficiency95%-99.5%Impacts operational costs
Short Circuit Impedance4%-20%Affects fault current limitation
Insulation ClassA (105 C) to C (220 C)Determines thermal endurance

5. Application Areas

Major sectors include:

  • Electricity distribution networks (urban/rural)
  • Renewable energy systems (wind/solar grid-tied inverters)
  • Industrial machinery (CNC, smelters, compressors)
  • Railway traction systems (15kV-25kV conversion)
  • Data centers (HVDC conversion systems)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens EnergyBlue TransformersEnvironmentally friendly synthetic ester insulation
Asea Brown Boveri (ABB)550kV UHV Transformer 500kV DC transmission capability
General Electric (GE)Premier SeriesSmart monitoring with Predictivity analytics
Mitsubishi Electric330MVA Traction TransformerCompact design for Shinkansen trains

7. Selection Guidelines

Key considerations:

  • Voltage levels (primary/secondary requirements)
  • Load profile (continuous vs. intermittent duty)
  • Cooling requirements (ONAN/ONAF/OFAF modes)
  • Environmental conditions (temperature, altitude, seismic zones)
  • Protection features (IP rating, fire resistance)
  • Smart grid compatibility (IoT sensor integration)

Case Study: Wind farm grid connection selected 33/132kV ONAF-cooled transformer with 12% impedance to meet fault ride-through requirements.

8. Industry Trends

Current development directions:

  • Smart transformers with real-time monitoring (IEEE C57.163 compliant)
  • Amorphous metal core adoption (50% core loss reduction)
  • Hydrogen-cooled systems for offshore applications
  • Modular solid-state transformer (SST) prototypes (DOE GRID DATA initiative)
  • Increased demand for 132kV+ mobile transformers in disaster recovery

Market forecasts indicate 6.2% CAGR through 2030, driven by grid modernization and EV charging infrastructure expansion.

RFQ BOM Call Skype Email