Power Transformers

Image Part Number Description / PDF Quantity Rfq
DST-4-16

DST-4-16

Signal Transformer

PWR XFMR LAMINATED 6VA TH

1317

161F40

161F40

Hammond Manufacturing

PWR XFMR LAMINATED 4.4VA TH

11

PL10-20-130B

PL10-20-130B

Tamura

PWR XFMR LAMINATED 10VA TH

0

1182L12

1182L12

Hammond Manufacturing

PWR XFMR TORO 50VA CHAS MT

6

F5-36

F5-36

Triad Magnetics

PWR XFMR LAMINATED 12VA CHAS MT

0

62002

62002

Talema

PWR XFMR TORO 1.6VA CHAS MT

0

166J18

166J18

Hammond Manufacturing

PWR XFMR LAMINATED 18VA CHAS MT

18

FP24-250-B

FP24-250-B

Triad Magnetics

PWR XFMR LAMINATED 6VA TH

504

A41-43-16

A41-43-16

Signal Transformer

PWR XFMR LAMINATED 43VA CHAS MT

31

F36-550-C2

F36-550-C2

Triad Magnetics

PWR XFMR LAMINATED 20VA TH

0

62083

62083

Talema

PWR XFMR TORO 50VA CHAS MT

0

VPS28-6250

VPS28-6250

Triad Magnetics

PWR XFMR LAMINATED 175VA CHAS MT

54718

160J10

160J10

Hammond Manufacturing

PWR XFMR LAMINATED 10VA TH

5

F20-300

F20-300

Triad Magnetics

PWR XFMR LAMINATED 6VA TH

27

266G12

266G12

Hammond Manufacturing

PWR XFMR LAMINATED 6.3VA CHAS MT

9

290EX

290EX

Hammond Manufacturing

PWR XFMR LAMINATED CHAS MT

2

F5-56

F5-56

Triad Magnetics

PWR XFMR LAMINATED 12VA CHAS MT

242

160H56

160H56

Hammond Manufacturing

PWR XFMR LAMINATED 24VA TH

18

187D28

187D28

Hammond Manufacturing

PWR XFMR LAMINATED 30VA CHAS MT

27

160E120

160E120

Hammond Manufacturing

XFRMR LAMINATED 1.2VA THRU HOLE

44

Power Transformers

1. Overview

Power transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. They enable voltage conversion (step-up/step-down) while maintaining galvanic isolation. These components are fundamental in power distribution systems, renewable energy integration, and industrial equipment, ensuring efficient energy transmission and voltage level adaptation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Distribution TransformersMedium voltage conversion (1kV-36kV), compact designUrban power grids, residential areas
Transmission TransformersHigh voltage (66kV-800kV), grid stability focusSubstations, long-distance power lines
Instrument TransformersMeasurement and protection (CT/VT types)Energy metering, relay protection
Specialty TransformersCustom configurations (furnace, traction, marine)Industrial furnaces, railway systems

3. Structure and Components

Typical construction includes:

  • Core: Grain-oriented silicon steel laminations for magnetic flux path
  • Windings: Primary/secondary copper/aluminum coils with insulation layers
  • Insulation: Mineral oil, synthetic esters, or solid materials (e.g., epoxy)
  • Cooling System: Radiator tanks, fans, or forced-oil circulation
  • Tap Changer: On-load/off-load voltage regulation mechanism
  • Protection: Buchholz relay, pressure relief valves, temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Rated Voltage230V-800kVDetermines system compatibility
Power Capacity50kVA-1000MVADefines energy throughput
Voltage Ratio1:1 to 1:20Specifies transformation ratio
Efficiency95%-99.5%Impacts operational costs
Short Circuit Impedance4%-20%Affects fault current limitation
Insulation ClassA (105 C) to C (220 C)Determines thermal endurance

5. Application Areas

Major sectors include:

  • Electricity distribution networks (urban/rural)
  • Renewable energy systems (wind/solar grid-tied inverters)
  • Industrial machinery (CNC, smelters, compressors)
  • Railway traction systems (15kV-25kV conversion)
  • Data centers (HVDC conversion systems)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens EnergyBlue TransformersEnvironmentally friendly synthetic ester insulation
Asea Brown Boveri (ABB)550kV UHV Transformer 500kV DC transmission capability
General Electric (GE)Premier SeriesSmart monitoring with Predictivity analytics
Mitsubishi Electric330MVA Traction TransformerCompact design for Shinkansen trains

7. Selection Guidelines

Key considerations:

  • Voltage levels (primary/secondary requirements)
  • Load profile (continuous vs. intermittent duty)
  • Cooling requirements (ONAN/ONAF/OFAF modes)
  • Environmental conditions (temperature, altitude, seismic zones)
  • Protection features (IP rating, fire resistance)
  • Smart grid compatibility (IoT sensor integration)

Case Study: Wind farm grid connection selected 33/132kV ONAF-cooled transformer with 12% impedance to meet fault ride-through requirements.

8. Industry Trends

Current development directions:

  • Smart transformers with real-time monitoring (IEEE C57.163 compliant)
  • Amorphous metal core adoption (50% core loss reduction)
  • Hydrogen-cooled systems for offshore applications
  • Modular solid-state transformer (SST) prototypes (DOE GRID DATA initiative)
  • Increased demand for 132kV+ mobile transformers in disaster recovery

Market forecasts indicate 6.2% CAGR through 2030, driven by grid modernization and EV charging infrastructure expansion.

RFQ BOM Call Skype Email
Top