Current Sense Transformers

Image Part Number Description / PDF Quantity Rfq
CR5RL-101

CR5RL-101

CR Magnetics, Inc.

CURR SENSE XFMR 100A IN-LINE

0

CR8348-2000-D

CR8348-2000-D

CR Magnetics, Inc.

CURR SENSE XFMR 50A T/H

0

2277640

2277640

Phoenix Contact

CURR SENSE XFMR 300A DIN RAIL

0

AS-403

AS-403

Amgis

XFRMR CURR 10A 1:100 VRT

0

CR5RBL-201

CR5RBL-201

CR Magnetics, Inc.

CURR SENSE XFMR 200A

0

CR5SFT-102

CR5SFT-102

CR Magnetics, Inc.

CURR SENSE XFMR 1000A CHAS MNT

0

CR6ASFT-122

CR6ASFT-122

CR Magnetics, Inc.

CURR SENSE XFMR 1200A CHAS MNT

0

AS-404

AS-404

Amgis

XFRMR CURR 50A 1:100 VRT

0

CTG050

CTG050

Carlo Gavazzi

CORE BALANCE TRANSFORM 050MM

0

PL1961NLT

PL1961NLT

PulseR (iNRCORE

XFM CST-37 CURR SENSE 1:1: PBC

0

PL2264NLT

PL2264NLT

PulseR (iNRCORE

XFMR CURRENT SENSE 1:100 PBC

0

AS-407

AS-407

Talema

CURR SENSE XFMR 1:500 80A T/H

0

PL2035NLT

PL2035NLT

PulseR (iNRCORE

XFMR CURRENT SENSE 1:50 T& PBC

0

2277022

2277022

Phoenix Contact

CURR SENSE XFMR 1:20 100A DIN RL

0

CT005001

CT005001

Red Lion

CURR SENSE XFMR

0

2910326

2910326

Phoenix Contact

SET CONSISTING OF 2 COMPONENTS:

0

CR5RL-122

CR5RL-122

CR Magnetics, Inc.

CURR SENSE XFMR 1200A IN-LINE

0

ELCT5-88

ELCT5-88

Wickmann / Littelfuse

CT 100:1 WITH FLUX COND 88MM

44

A82-1050

A82-1050

Carlo Gavazzi

1PH CURR XFMR 0-20MA OUTPUT

0

CR2DARL-500

CR2DARL-500

CR Magnetics, Inc.

CURR SENSE XFMR 50A IN-LINE

0

Current Sense Transformers

1. Overview

Current Sense Transformers (CSTs) are specialized electromagnetic devices designed to accurately detect and measure alternating current (AC) in electrical circuits. By converting primary current signals into proportional secondary currents or voltages, CSTs enable safe and reliable monitoring for control systems, energy management, and protection circuits. Their importance in modern technology spans power electronics, industrial automation, renewable energy systems, and smart grid infrastructure, where precise current measurement is critical for efficiency optimization and system safety.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Open-Circuit Core CSTLow cost, wide current range, moderate accuracySmart meters, household appliances
Closed-Loop Core CSTHigh accuracy (0.1%~0.5%), low phase errorMotor drives, precision power supplies
Hall Effect IntegrationDC/AC hybrid measurement, galvanic isolationElectric vehicle BMS, energy storage systems
High-Frequency CSTOperates >100kHz, minimized core lossWireless charging systems, induction heating
Miniature Surface-MountCompact size, PCB-mountableConsumer electronics, IoT devices

3. Structure and Components

Typical CST construction includes: - Magnetic Core: Made from ferrite, silicon steel, or nanocrystalline materials to ensure high permeability and low loss - Primary Winding: Single-turn or multi-turn conductor depending on current range - Secondary Winding: Multi-turn coil with precise turns ratio for signal scaling - Insulation System: Epoxy resin or plastic housing meeting UL/IEC dielectric standards - Termination: Screw terminals, PCB pins, or integrated connectors Advanced models incorporate shielding layers and temperature-compensated materials for enhanced stability.

4. Key Technical Specifications

ParameterTypical RangeSignificance
Current Ratio100:1 to 5000:1Determines scaling factor for measurement
Accuracy Class0.1% to 1%Critical for metering and control precision
Frequency Range50Hz-1MHzDictates application suitability
Phase Shift<1 Affects power factor calculation accuracy
Isolation Voltage2.5kV-10kVEnsures safety in high-voltage systems
Operating Temp.-40 C to +125 CEnvironmental reliability indicator

5. Application Fields

Major industries and equipment utilizing CSTs include:

  • Energy Sector: Smart grids, substation protection relays
  • Industrial Automation: Variable frequency drives, PLC systems
  • Renewable Energy: Solar inverters, wind turbine converters
  • Transportation: EV charging stations, traction control systems
  • Consumer Electronics: Smart home appliances, power banks

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
ABBACS7112kV isolation, 1% accuracy for EV charging
LEMHASS 25-SOpen-loop sensor with 120A measurement range
TE ConnectivityCurrentSense 55512Surface-mount design for PCB integration
VacuumschmelzeDIN43858High-frequency capability up to 500kHz
Allegro MicroACS37610Digital output with I C interface

7. Selection Guidelines

Key considerations for CST selection:

  1. Required current ratio and measurement range
  2. Accuracy demands (metering vs. protection applications)
  3. Environmental conditions (temperature, humidity, vibration)
  4. Frequency characteristics of the target circuit
  5. Space constraints and mounting requirements
  6. Cost-performance balance for mass production

Example: For PV inverter applications, select a closed-loop core CST with >200kHz bandwidth and IP67 rating to ensure reliable operation under fluctuating environmental conditions.

8. Industry Trends

Emerging trends shaping CST development include:

  • Integration with digital interfaces (CAN, Modbus) for smart systems
  • Wide bandgap semiconductor compatibility (SiC/GaN circuits)
  • Nano-material core adoption for reduced size and weight
  • AI-enhanced error compensation algorithms
  • Increased adoption in EV infrastructure and energy storage systems

Market forecasts indicate 8.2% CAGR through 2030, driven by renewable energy integration and industrial IoT expansion.

RFQ BOM Call Skype Email
Top