Current Sense Transformers

Image Part Number Description / PDF Quantity Rfq
CR2RL-500

CR2RL-500

CR Magnetics, Inc.

CURR SENSE XFMR 50A CHAS MNT

0

2276117

2276117

Phoenix Contact

CURR SENSE XFMR 1:30 150A DIN RL

0

A82-10100

A82-10100

Carlo Gavazzi

1PH CURR XFMR 0-20MA OUTPUT

0

AS-321

AS-321

Amgis

XFRMR CURR 15A 1:100 VRT

0

PH9500.100NLT

PH9500.100NLT

PulseLarsen Antenna

CURRENT SENSE, SIDECAR, SM

1178

2276120

2276120

Phoenix Contact

CURR SENSE XFMR 1:40 200A DIN RL

0

PH9500.065NLT

PH9500.065NLT

PulseLarsen Antenna

CURRENT SENSE, SIDECAR, SM

193

CT500/5

CT500/5

Mueller Electric Co.

CURRENT TRANSFORMER

10

ACST-260-1

ACST-260-1

Zettler Magnetics

CURR SENSE XFMR 30A TH

446

CT-0100-D10

CT-0100-D10

Wickmann / Littelfuse

CURR SENSE XFMR 100:5 DONUT

1

A82-20100

A82-20100

Carlo Gavazzi

1PH CURR XFMR 4-20MA OUTPUT

0

PH9505.070NLT

PH9505.070NLT

PulseLarsen Antenna

XFRMR CURRENT SENSE 1:70 SMD

140

CR5ARL-101

CR5ARL-101

CR Magnetics, Inc.

CURR SENSE XFMR 100A IN-LINE

0

CTG070

CTG070

Carlo Gavazzi

CORE BALANCE TRANSFORM 070MM

0

CR2DARL-301

CR2DARL-301

CR Magnetics, Inc.

CURR SENSE XFMR 300A IN-LINE

0

CR2DARL-101

CR2DARL-101

CR Magnetics, Inc.

CURR SENSE XFMR 100A IN-LINE

0

CR5ARL-751

CR5ARL-751

CR Magnetics, Inc.

CURR SENSE XFMR 750A IN-LINE

0

8SHT-601-E

8SHT-601-E

Wickmann / Littelfuse

CURRENT TRANSF 600:5 50VA 3.25"

0

CR8349-1000

CR8349-1000

CR Magnetics, Inc.

CURR SENSE XFMR 50A T/H

0

CR2550-Y

CR2550-Y

CR Magnetics, Inc.

CURR SENSE XFMR IN-LINE

0

Current Sense Transformers

1. Overview

Current Sense Transformers (CSTs) are specialized electromagnetic devices designed to accurately detect and measure alternating current (AC) in electrical circuits. By converting primary current signals into proportional secondary currents or voltages, CSTs enable safe and reliable monitoring for control systems, energy management, and protection circuits. Their importance in modern technology spans power electronics, industrial automation, renewable energy systems, and smart grid infrastructure, where precise current measurement is critical for efficiency optimization and system safety.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Open-Circuit Core CSTLow cost, wide current range, moderate accuracySmart meters, household appliances
Closed-Loop Core CSTHigh accuracy (0.1%~0.5%), low phase errorMotor drives, precision power supplies
Hall Effect IntegrationDC/AC hybrid measurement, galvanic isolationElectric vehicle BMS, energy storage systems
High-Frequency CSTOperates >100kHz, minimized core lossWireless charging systems, induction heating
Miniature Surface-MountCompact size, PCB-mountableConsumer electronics, IoT devices

3. Structure and Components

Typical CST construction includes: - Magnetic Core: Made from ferrite, silicon steel, or nanocrystalline materials to ensure high permeability and low loss - Primary Winding: Single-turn or multi-turn conductor depending on current range - Secondary Winding: Multi-turn coil with precise turns ratio for signal scaling - Insulation System: Epoxy resin or plastic housing meeting UL/IEC dielectric standards - Termination: Screw terminals, PCB pins, or integrated connectors Advanced models incorporate shielding layers and temperature-compensated materials for enhanced stability.

4. Key Technical Specifications

ParameterTypical RangeSignificance
Current Ratio100:1 to 5000:1Determines scaling factor for measurement
Accuracy Class0.1% to 1%Critical for metering and control precision
Frequency Range50Hz-1MHzDictates application suitability
Phase Shift<1 Affects power factor calculation accuracy
Isolation Voltage2.5kV-10kVEnsures safety in high-voltage systems
Operating Temp.-40 C to +125 CEnvironmental reliability indicator

5. Application Fields

Major industries and equipment utilizing CSTs include:

  • Energy Sector: Smart grids, substation protection relays
  • Industrial Automation: Variable frequency drives, PLC systems
  • Renewable Energy: Solar inverters, wind turbine converters
  • Transportation: EV charging stations, traction control systems
  • Consumer Electronics: Smart home appliances, power banks

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
ABBACS7112kV isolation, 1% accuracy for EV charging
LEMHASS 25-SOpen-loop sensor with 120A measurement range
TE ConnectivityCurrentSense 55512Surface-mount design for PCB integration
VacuumschmelzeDIN43858High-frequency capability up to 500kHz
Allegro MicroACS37610Digital output with I C interface

7. Selection Guidelines

Key considerations for CST selection:

  1. Required current ratio and measurement range
  2. Accuracy demands (metering vs. protection applications)
  3. Environmental conditions (temperature, humidity, vibration)
  4. Frequency characteristics of the target circuit
  5. Space constraints and mounting requirements
  6. Cost-performance balance for mass production

Example: For PV inverter applications, select a closed-loop core CST with >200kHz bandwidth and IP67 rating to ensure reliable operation under fluctuating environmental conditions.

8. Industry Trends

Emerging trends shaping CST development include:

  • Integration with digital interfaces (CAN, Modbus) for smart systems
  • Wide bandgap semiconductor compatibility (SiC/GaN circuits)
  • Nano-material core adoption for reduced size and weight
  • AI-enhanced error compensation algorithms
  • Increased adoption in EV infrastructure and energy storage systems

Market forecasts indicate 8.2% CAGR through 2030, driven by renewable energy integration and industrial IoT expansion.

RFQ BOM Call Skype Email