Accessories

Image Part Number Description / PDF Quantity Rfq
DXX05-SI

DXX05-SI

Teledyne LeCroy

SOLDER IN LEAD W/5 RESISTORS

0

PK-ZS-006

PK-ZS-006

Teledyne LeCroy

RIGHT ANGLE SOCKET 4/PC

1

PK106-2

PK106-2

Teledyne LeCroy

SING LEAD ADAPT PP005/PPE

1

PK007-017

PK007-017

Teledyne LeCroy

SINGLE LEAD ADAPTER

13

PACC-ZD008

PACC-ZD008

Teledyne LeCroy

Y-LEAD ADAPTER

1

T3SA3000-RFM-KIT

T3SA3000-RFM-KIT

Teledyne LeCroy

REFLECTION MEASURE KIT T3SA SERI

0

PK007-008

PK007-008

Teledyne LeCroy

IC CAP FOR .5MM PKG OF 10

12

PK1-5MM-105

PK1-5MM-105

Teledyne LeCroy

INSULATING CAP

1

HDO4K-SOFTCASE

HDO4K-SOFTCASE

Teledyne LeCroy

CASE SOFT CARRYING FOR HDO4000

0

PK102

PK102

Teledyne LeCroy

PP004/PP005 GEN ACCES

5

PK007-011

PK007-011

Teledyne LeCroy

IC-CAP FOR 1. MM PACK 10

1

HDO4K-USB2BUS TD

HDO4K-USB2BUS TD

Teledyne LeCroy

USB 2.0 BUS DECODE OPTION

0

PK007-029

PK007-029

Teledyne LeCroy

GROUND LEAD WITH 4 MM PLUG

12

PK007-013

PK007-013

Teledyne LeCroy

GND BLADE PK OF 5

4

DX10-QC

DX10-QC

Teledyne LeCroy

REPLACEMENT QC LEAD SET DX10

0

PACC-LD005

PACC-LD005

Teledyne LeCroy

GROUND LEAD (QTY 4)

6

PK003

PK003

Teledyne LeCroy

PRB ACCESS PP061/62/64

1

PACC-ZD009

PACC-ZD009

Teledyne LeCroy

MICRO SPRINGLOADED ZD DIFF PRB

0

T3SA3000-RLB

T3SA3000-RLB

Teledyne LeCroy

RETURN LOSS BRIDGE FOR T3SA SERI

1

DL-HCM-HITEMP

DL-HCM-HITEMP

Teledyne LeCroy

DL-HCM SERIES HIGH-TEMPERATURE S

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email