Accessories

Image Part Number Description / PDF Quantity Rfq
PK-ZS-019

PK-ZS-019

Teledyne LeCroy

FREEHAND PROBE HOLDER ZS4000

2

AP034-DA10

AP034-DA10

Teledyne LeCroy

DIV BY 10 ATTENUATOR PLUG ON A

9

HDO4K-DPHYBUS D

HDO4K-DPHYBUS D

Teledyne LeCroy

D-PHY BUS DECODE OPTION

0

MSO-DLS-18

MSO-DLS-18

Teledyne LeCroy

16" DIGITAL LEAD SET

1

MSO-3M

MSO-3M

Teledyne LeCroy

18 PIN 3M INTERFACE CABLE

0

PP005-GL11

PP005-GL11

Teledyne LeCroy

11CM GND LEAD

31

PROBUS-CF01

PROBUS-CF01

Teledyne LeCroy

PROBUS EXTENDER AP03X

2

HDO4K-SPIBUS TD

HDO4K-SPIBUS TD

Teledyne LeCroy

SPI BUS TRIGGER DECODE OPTION

0

PK1-5MM-117

PK1-5MM-117

Teledyne LeCroy

FLXBL ADPT 5.0 TO 4MM BANANA PLG

21

RP4000-MCX-CABLE-UFL

RP4000-MCX-CABLE-UFL

Teledyne LeCroy

QTY. 3 3 GHZ MCX TO U.FL ULTRA-M

0

WS3K-CAN FDBUS TD

WS3K-CAN FDBUS TD

Teledyne LeCroy

CAN FD TRGGR/DCD WAVESURFER 3000

0

PK106-1

PK106-1

Teledyne LeCroy

DUAL LEAD ADAPT PP005/PPE

13

WS3K-EMB

WS3K-EMB

Teledyne LeCroy

EMBEDDED SOFTWARE OPTION FOR WS3

0

HDO4K-ARINC429BUS DSYMBOLIC

HDO4K-ARINC429BUS DSYMBOLIC

Teledyne LeCroy

ARINC 429 SYMBOLIC DECODE OPTION

0

PK006-1

PK006-1

Teledyne LeCroy

RPLCMNT DUAL LEAD ADAPT

6

HVFO100-1X-TIP-U

HVFO100-1X-TIP-U

Teledyne LeCroy

OSCOPE PROBE X1 60MHZ 1M

2

PK-ZS-023

PK-ZS-023

Teledyne LeCroy

STRAIGHT PIN ZS4000 4/PC

1

PK1-5MM-112

PK1-5MM-112

Teledyne LeCroy

DUAL ADAPTER 5.0 TO 0.8MM SCKT

7

PK007-003

PK007-003

Teledyne LeCroy

ADJUSTMENT TOOL

1

HDO4K-CANBUS TD

HDO4K-CANBUS TD

Teledyne LeCroy

CAN TRIGGER DECODE OPTION

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email